نتایج جستجو برای: implant complication

تعداد نتایج: 116105  

Journal: :journal of dentistry, tehran university of medical sciences 0
amir reza rokn associate professor, dental implant research center, department of periodontics, school of dentistry, tehran university of medical sciences, tehran, iran. neda sajedinejad postgraduate student of periodontics. tehran university of medical sciences, tehran, iran. hosnieh yousefyfakhr postgraduate student of periodontics. tehran university of medical sciences, tehran, iran. samare badri general dentist, private practice, tehran university of medical sciences, tehran, iran.

pre-implant disease is an inflammatory process that affects the surrounding tissues of a functional osseointegrated implant. it is usually the result of a disequilibrium between the micro-flora and the defense system. this case reports a 57-year-old man with unusual bone loss around dental implants. this was an unusual case of peri-implantitis that occurred only in the implants on one side of t...

Journal: :journal of dentistry, tehran university of medical sciences 0
anshul jain senior resident, department of oral and maxillofacial surgery, maulana azad institute of dental sciences, new delhi, india. shridhar d baliga professor, (head of the department), department of oral and maxillofacial surgery, kle vk institute of dental sciences, belgaum, karnataka, india.

one of the complications during a routine dental implant placement is accidental ingestion of the implant instruments, which can happen when proper precautions are not taken. appropriate radiographs should be taken to locate the correct position of foreign body; usually the foreign body passes asymptomatically from gastrointestinal tract but sometimes it may lead to intestinal obstruction, perf...

ژورنال: مجله دندانپزشکی 2013
اصلانی, پویا , علی خاصی, مرضیه ,

Background and Aims The purpose of this study was to evaluate the survival rate, mean bone loss and post operative complication of implants inserted in All-on-4 technique . Materials and Methods: The literature was searched using keywords angled implant, All-on-4, tilted implant and graftless technique in the last 10 years (2001 to 2011) and clinical trial article that evaluated survival rate a...

Journal: :Srpski arhiv za celokupno lekarstvo 2009

Capsular contraction is a frequent complication following breast augmentation. On the other hand, capsular weakness, a not widely recognized complication, may occur around the implant. A weak capsule allows the migration of the prosthesis to the lateral region of the thoracic region or inferiorly, towards the abdomen, due to gravitational forces. The cause of capsular weakness remains unresolve...

Journal: :the archives of bone and joint surgery 0
ali birjandi nejad orthopedic research center, shahid kamiab hospital, mashhad university of medical sciences mashhad, 91766-99199, iran. mohammad kaveh orthopedic research center, shahid kamiab hospital, mashhad university of medical sciences mashhad, 91766-99199, iran. amir reza fatehi orthopedic research center, shahid kamiab hospital, mashhad university of medical sciences mashhad, 91766-99199, iran. hami ashraf orthopedic research center, shahid kamiab hospital, mashhad university of medical sciences mashhad, 91766-99199, iran. mohammad h taraz jamshidi orthopedic research center, shahid kamiab hospital, mashhad university of medical sciences mashhad, 91766-99199, iran. mohammad hosein ebrahimzadeh orthopedic research center, shahid kamiab hospital, mashhad university of medical sciences mashhad, 91766-99199, iran.

this report is on a migration of a steinman pin into the posterior com department of the calf. it was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. the puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. accord ing to our literature review, migration of fixation pins through the kne...

Journal: :IOP conference series 2022

Abstract Implant-based restoration is currently seen to be a more reliable option with higher success rates. Biological and technological problems, on the other hand, are common. An implant insertion complication well known many loosening of abutment screw. Fractures implant-abutment may cause fail function efficiently as they leave fragment inside implant. This study aimed introduce modified d...

2016
Jae-Hong Lee Jong-Bin Lee Man-Yong Kim Joon-Ho Yoon Seong-Ho Choi Young-Taek Kim

PURPOSE The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected ...

Journal: :Clinical oral implants research 2012
Pablo Galindo-Moreno Miguel Padial-Molina Gustavo Avila Hector F Rios Pedro Hernández-Cortés Hom-Lay Wang

BACKGROUND Migration of dental implants into the maxillary sinus is an uncommon, but increasingly reported complication. Implant migration may result from initial lack of primary stability, intrasinusal and nasal pressure changes, autoimmune reaction to the implant or incorrect distribution of occlusal forces. This retrospective study aims at analyzing the factors that may influence implant mig...

2014
Anshul Jain Shridhar D Baliga

One of the complications during a routine dental implant placement is accidental ingestion of the implant instruments, which can happen when proper precautions are not taken. Appropriate radiographs should be taken to locate the correct position of foreign body; usually the foreign body passes asymptomatically from gastrointestinal tract but sometimes it may lead to intestinal obstruction, perf...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید