نتایج جستجو برای: iii sensor

تعداد نتایج: 444671  

The characterization of and construction of a new optical sensor based on the immobilization of Pyrocatechol Violet on a triacetylcellulose membrane was described to for the determination of bismuth (III) in real samples. The interaction between sensing membrane and bismuth (III) was caused at pH 3.80 in acetate buffer solution and the color changed from yellow to blue along with the appearance...

Journal: :international journal of heterocyclic chemistry 0
fariba mehranfar department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran arezoo ghaemi department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran haman tavakkoli department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran

a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two mont...

Arezoo Ghaemi, Fariba Mehranfar Haman Tavakkoli

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response tim...

Arezoo Ghaemi, Fariba Mehranfar Haman Tavakkoli

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...

Arezoo Ghaemi, Fariba Mehranfar Haman Tavakkoli

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...

Journal: :desert 2013
m. shirazi gh.r. zehtabian h.r. matinfar s.k. alavipanah

soil salinity has been a large problem in arid and semi arid regions. preparation of such maps is useful for natural resource managers. old methods of preparing such maps require a lot of time and cost. multi-spectral remotely sensed dates due to the broad vision and repeating of these imageries is suitable for provide saline soil maps. this investigation is conducted to provide saline soil map...

Journal: :desert 0
m. shirazi m.sc graduate, university of tehran, karaj, iran gh.r. zehtabian professor, university of tehran, karaj, iran h.r. matinfar assistant professor, university of lorestan, khoram abad, iran s.k. alavipanah professor, university of tehran, tehran, iran

soil salinity has been a large problem in arid and semi arid regions. preparation of such maps is useful for natural resource managers. old methods of preparing such maps require a lot of time and cost. multi-spectral remotely sensed dates due to the broad vision and repeating of these imageries is suitable for provide saline soil maps. this investigation is conducted to provide saline soil map...

A. Abbaspourb A. H. Kianfar A. Naghashian Haghighia A. Shokrollahi,

A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M  with Nernstian slope of 19...

Arezoo Ghaemi, Fariba Mehranfar Haman Tavakkoli

A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two month...

E. Baghdar M. Darvishpour M.H. Fekri

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید