نتایج جستجو برای: hold up volume

تعداد نتایج: 1250853  

Journal: :international journal of occupational hygiene 0
ali karimi occupational health department, school of public health and nutrition, shiraz university of medical sciences, shiraz, iran and occupational health eng. department, school of public health, tehran university of medical sciences, tehran, iran. farideh golbabaei occupational health eng. department, school of public health, tehran university of medical sciences, tehran, iran. mohammadreza mehrnia biotechnology group, school of chemical engineering, university college of engineering, university of tehran, tehran, iran. kazem mohammad epidemiology and biostatistics department, school of public health, tehran university of medical sciences, tehran, iran. masoud neghab occupational health department, school of public health and nutrition, shiraz university of medical sciences, shiraz, iran. ahmad nikpey occupational health department, school of public health, qazvin university of medical sciences, qazvin, iran.

a laboratory stirred tank bioreactor with six single and dual-impeller configurations was tested to obtain the optimum operating conditions for future biological processes. six impeller combinations consisting of three basic impeller types, namely rushton turbine (rt), pitched 4blade (p4b) and pitched 2blade (p2b) downward flow were investigated in 1.77 l bioreactor working volume. power consum...

Journal: :BDJ in practice 2021

Journal: :Journal of Cell Biology 2002

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2010
fatemeh saadat gharehbagh sayed mohammad ali mousavian,

an experimental study has been conducted on the hydrodynamics of a stage mixer-settler to obtain an appropriate design. in this paper several tests was performed to investigate full factorial design of experiments. since each test was repeated seven times, the repeatability of the test was confirmed (p=1 bar and t=25 °c). sauter diameter was determined by photographing both the mixer and settle...

Journal: :Lc Gc North America 2023

There are as many measurement values of the true column hold-up volume, V0, techniques applied to evaluate this most important property in liquid chromatography (LC). The relative errors made on V0 measurements using conventional “non-retained” markers—such acetone, uracil, or thiourea reversed-phase (RPLC), benzene acenaphthene hydrophilic interaction (HILIC)—can be large ±30%. This situation ...

Journal: :Journal of Financial Intermediation 2005

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید