نتایج جستجو برای: heterogeneous phantom

تعداد نتایج: 142666  

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, govt. rajaji hospital and madurai medical college, maduari-625 020, india v. ramakrishnan deptartment of laser studies, madurai kamaraj university, madurai, tamil nadu, india

background: the heterogeneous composition of the human body presents numerous tissue types and cavities with widely differing radiologic properties. the aim of the present work was to develop a low cost homogeneous and heterogeneous phantom and the absorbed dose were measured by ionization chamber for different radiotherapy treatment techniques and compared with treatment planning system absorb...

ژورنال: پژوهش در پزشکی 2018

Background: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. Breast tissue composition is one of the factors affecting on DgN values. In this study both homogeneous and heterogeneous breast tissue is assumed and its impact on DgN values are evaluated. Methods: Homogeneous breast phantom with diffe...

Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...

Journal: :iranian journal of radiation research 0
i. setilo medical physics department, faculty of health sciences, university of the free state, bloemfontein 9300, south africa f.c.p. du plessis medical physics department, faculty of health sciences, university of the free state, bloemfontein 9300, south africa

background:  radiochromic film is used for radiation dose measurement, xr-rv3 is used in fluoroscopy and ebt2 film in radiation therapy. the aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. materials and methods: comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.  Materials and Methods: Th...

du Plessis, F.C.P., Setilo, I.,

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

C. Geng, C. Gong, D. Shu, H. Yu, S. Fatemi, W. Shao, X. Tang,

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

بخشنده, محسن, عابدی فیروزجاه, رزاق, نیک فرجام, ابوالفضل,

Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiothe...

2017
Sossena Wood Narayanan Krishnamurthy Tales Santini Shailesh Raval Nadim Farhat John Andy Holmes Tamer S. Ibrahim

OBJECTIVE The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications. MATERIALS AND METHODS An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application tha...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید