نتایج جستجو برای: gyn brachytherapy phantom
تعداد نتایج: 25431 فیلتر نتایج به سال:
Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...
introduction dosimetric accuracy is a major issue in the quality assurance (qa) program for treatment planning systems (tps). an important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. in brachytherapy (bt) of gynecological (gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
PURPOSE Positron emission tomography (PET) provides physiologic information that is not available from computed tomography (CT) or magnetic resonance studies. PET images may allow more accurate delineation of three-dimensional treatment planning target volumes of brachytherapy gynecologic (GYN) implants. This study evaluates the feasibility of using PET as the sole source of target, normal stru...
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
The objective of this work is to present commissioning procedures to clinically implement a three-dimensional (3D), image-based, treatment-planning system (TPS) for high-dose-rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction ...
introduction based on task group no. 43 (tg-43u1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. the experimental determination of tg-43 parameters is usually performed in water-equivalent solid phantoms. the purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. materials and methods t...
Purpose: To evaluate the radiation attenuation properties of PC-ISO, a bio-compatible, sterilizable 3D printing material and its suitability for customized gynecologic (GYN) brachytherapy 15 applicators. Method: A custom radiochromic film dosimetry apparatus was 3D-printed in PC-ISO. The apparatus contained a single catheter channel and a slit to hold a radiochromic segment. A brachytherapy dos...
introduction after the publication of task group number 43 dose calculation formalism by the american association of physicists in medicine (aapm), this method has been known as the most common dose calculation method in brachytherapy treatment planning. in this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...
نمودار تعداد نتایج جستجو در هر سال