Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran ghorban safaeian m.sc., in medical physics, mashhad university of medical sciences, mashhad, iran mohammad hosein bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahram baiani m.sc., in medical engineering, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

Journal: :iranian journal of medical physics 0
m. sedaghat ph.d. student in medical physics, university of sherbrooke, canada. m.h zahmatkesh assistant professor, novin medical radiation institute, tehran, iran. r. jaberi m.sc. in medical physics, cancer institute, imam hospital, tums, tehran, iran. sh. akhalghpoor assistant professor, faculty of medicine, tums & novin medical radiation institute, tehran, iran. m. allahverdi assistant professor, dept. of medical physics, faculty of medicine, tums & cancer institute of imam hospital, tehran, iran.

introduction: despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. in the current work, the feasibility of using a normoxic polymer gel dosimeter named magica has been investigated for use in our clinical brachytherapy applic...

M. Allahverdi M. Sedaghat M.H Zahmatkesh R. Jaberi Sh. Akhalghpoor

Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...

Journal: :iranian journal of radiation research 0
mahbod sedaghat department of medical physics, tehran university of medical sciences, tehran, iran m.h. zahmatkesh r. jaberi sh. akhlaghpoor m. allahverdi

abstractbackground: polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. in the current work, we present our preliminary results of investigating capability of x-r...

M. Allahverdi, M.H. Zahmatkesh, Mahbod Sedaghat, R. Jaberi, Sh. Akhlaghpoor,

ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

A R Montazerabadi A Takavar M H Zahmatkesh M Keshtkar,

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

2017
E Maynard M Hilts

This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...