نتایج جستجو برای: gamma knife monte carlo code sdd

تعداد نتایج: 360235  

Alireza Shirazi, Atefeh Mahmoudi Ghazale Geraily, Masoume Bakhshi

Introduction: Stereotactic radiosurgery (SRS) is one of the conformal radiotherapy methods and Gamma Knife is a non-invasive SRS technique to treat intracranial lesions with 201 Co- 60 sources without need to surgery and bleeding. Beam penumbra phenomenon leads to irradiation outside the field and normal tissues. Therefore, considering it is momentous to attain the acceptable t...

Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...

Journal: :iranian journal of medical physics 0
ali aghaebrahimian department of physics, isfahan university of technology, isfahan, iran mohammad hassan alamatsaz department of physics, isfahan university of technology, isfahan, iran

introduction the gamma knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. dose calculations required in the system are performed by gammaplan code; in this code, brain tissue is considered uniform. in the present study, we evaluated the effect of gamma knife system on the obtained dose through simulating a real h...

ژورنال: سنجش و ایمنی پرتو 2020

Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...

Journal: :iranian journal of medical physics 0
tayeb allahverdi pourfallah biochemistry and biophysics dept., faculty of medicine, mazandaran university of medical sciences, sari, iran

introduction polymer gel dosimeters offer a practical solution to 3d dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. in this study, egsnrc calculated and pagat polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of gamma knife in homogeneous and inhomogeneous phantoms were compared with eac...

2007
W Xiong D Huang L Lee J Feng K Morris E Calugaru C Burman J Li C-M Ma

Currently the Gamma Knife system is accompanied with a treatment planning system, Leksell GammaPlan (LGP) which is a standard, computer-based treatment planning system for Gamma Knife radiosurgery. In LGP, the dose calculation algorithm does not consider the scatter dose contributions and the inhomogeneity effect due to the skull and air cavities. To improve the dose calculation accuracy, Monte...

Journal: :Medical physics 1999
J Y Cheung K N Yu R T Ho C P Yu

The Monte Carlo technique and GafChromic films were employed to verify the accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (type B) radiosurgery when plugged collimator helmets were used. The EGS4 Monte Carlo code was used to calculate the dose distribution along the x, y, and z axes when a single shot was delivered at the center point (unit center point: x = 100, y...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
J Y Cheung K N Yu C P Yu R T Ho

The accuracy of the dose planning system (Leksell GammaPlan), used in Gamma Knife (type B) radiosurgery at extreme irradiation depths, was verified using the Monte Carlo technique. EGS4 Monte Carlo calculations were employed to calculate the dose distribution along the x, y and z axes for an irradiation relatively shallow in a spherical bony cavity water phantom. Two different sizes of the coll...

Journal: :Physics in medicine and biology 1999
J Y Cheung K N Yu R T Ho C P Yu

The Leksell Gamma Knife is a standard radiosurgical tool for treating brain lesions by directing beams of gamma radiation to a specific region. The diameter of the gamma beams is confined by collimator systems and available collimator sizes are 4, 8, 14 and 18 mm. The reduction in dose rate for each collimator helmet is called the output factor (OPF). Experimental determination of OPFs is diffi...

Mahdie Behjati Seyed Pezhman Shirmardi

Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the ef...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید