نتایج جستجو برای: force degradation
تعداد نتایج: 337221 فیلتر نتایج به سال:
Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations. Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ...
a simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (bus). the best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (ph = 3.00; 26.4 mm), at 35 °c. the sample was hydrodynamically injected at 50 mbar for 5 seco...
background and aims: elastomeric chains and niti coil springs are two major traction aids in orthodontic tooth movements. force degradation occurs over time in both groups, with higher percentages in elastic chains. the effects of environmental factors and some mouth rinses on this force decay have been previously studied. no study has been performed to evaluate the effect of current popular mo...
بررسی ارزش غذایی تاغ و عمل آوری آن با سود و آهک در مراحل مختلف رشدبا استفاده از روش کیسه های نایلونی
abstract this study is carried out to determine the chemical composition in the three vegetative stages of the haloxylon sp., degradation parameters, with adding naoh and ca(oh2 ). for this purpose, in may and october and january 2010 enough some haloxylon sp. of the ammary area was prepared. crude protein and ash percentage are decrease, neutral detergent fiber percentage with pragress stage ...
a capillary electrophoresis method was used for assay of some degradation products of carvedilol. the optimized parameters were as; running buffer 80 mm acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kv, temperature is 20 ºc and the wavelength range of 200-350 nm. the results indicate that the proposed ce method could effectively separate carvedilol from its de...
an ideal orthodontic force system should exert continuous light force. thus, many efforts have been made to improve the memory characteristics of elastomeric chains. the aim of this study was to compare elastomeric chains (ecs) claimed by their manufacturers to offer high memory with traditional ones according to their force-extension diagrams.in this in-vitro study, ecs were divided into six g...
Background. Elastomeric chains and NiTi coil springs are two major traction aids in orthodontic tooth movements. Force degradation occurs over time in both groups, with higher percentages in elastic chains. The effects of environmental factors and some mouth rinses on this force decay have been previously studied. No study has been performed to evaluate the effect of current popular mouth rinse...
A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...
The injectable composites were formulated from melt-derived 45S5 bioactive glass powder and gum tragacanth. The effect of tragacanth concentration (2 and 4 w/v%) and powder to liquid ratio (P/L= 1.5 to 2.5) on rheological properties, injectability, degradation, swelling, and bioactivity the composites was studied. With the increase of P/L ratio and tragacanth concentration, the force requ...
OBJECTIVE To analyze the in vitro force degradation of four different brands of elastomeric chains: American Orthodontics, Morelli, Ormco and TP Orthodontics. METHODS The sample consisted of 80 gray elastomeric chains that were divided into four groups according to their respective manufacturers. Chain stretching was standardized at 21 mm with initial force release ranging from 300 g to 370 g...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید