نتایج جستجو برای: fault characteristic frequencyl
تعداد نتایج: 237969 فیلتر نتایج به سال:
This with the integration of distributed generation (DG) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance DG tripping. This paper proposes a new tripping characteristic for directional overcurrent relays (DOCRs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networ...
This paper focuses on the problem of accurate Fault Characteristic Frequency (FCF) estimation of rolling bearing. Teager-Kaiser Energy Operator (TKEO) demodulation has been applied widely to rolling bearing fault detection. FCF can be extracted from vibration signals, which is pre-treatment by TEKO demodulation method. However, because of strong noise background of fault vibration signal, it is...
Low stacking fault energy face centered cubic (FCC) materials contain characteristic defect structures. Stacking fault tetrahedral are one of those rare structures that occur under special experimental conditions. For the first time, stacking fault tetrahedral were observed in Fe-30Mn-3Al-3Si twinning induced plasticity (TWIP) steel. Their presence resulted from a quenching heat treatment.
this with the integration of distributed generation (dg) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance dg tripping. this paper proposes a new tripping characteristic for directional overcurrent relays (docrs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networ...
This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...
low stacking fault energy face centered cubic (fcc) materials contain characteristic defect structures. stackingfault tetrahedral are one of those rare structures that occur under special experimental conditions. for the first time,stacking fault tetrahedral were observed in fe-30mn-3al-3si twinning induced plasticity (twip) steel. theirpresence resulted from a quenching heat treatment.
This paper compares fault position and Monte Carlo methods as the most common methods in stochastic assessment of voltage sags. To compare their abilities, symmetrical and unsymmetrical faults with different probability distribution of fault positions along the lines are applied in a test system. The voltage sag magnitude in different nodes of test system is calculated. The problem with the...
In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...
In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید