نتایج جستجو برای: eyesys

تعداد نتایج: 23  

Journal: :Journal of refractive surgery 1998
S Pardhan W A Douthwaite

BACKGROUND Various studies have compared the accuracy and repeatability of autokeratometers and videokeratoscopes using calibrated convex surfaces. We investigate the agreement between the Topcon KR-3500 autokeratometer and the EyeSys videokeratoscope on human corneas and calibrated convex surfaces. METHODS Measurements were obtained from 30 convex ellipsoidal buttons and 20 right eyes of 20 ...

Journal: :The British journal of ophthalmology 1995
W A Douthwaite

AIMS/BACKGROUND This study was carried out to assess the accuracy of the EyeSys videokeratoscope by using convex ellipsoidal surfaces of known form. METHODS PMMA convex ellipsoidal buttons were calibrated using Form Talysurf analysis which allowed subsequent calculation of the vertex radius and p value of the surface. The EyeSys videokeratoscope was used to examine the same ellipsoids. The ta...

Journal: :Arquivos brasileiros de oftalmologia 2010
Vinícius Silbiger de Stefano Luiz Alberto Soares Melo Junior Felipe Mallmann Paulo Schor

PURPOSE Many systems try to replace Placido disc-based topographers, such as those based in Scheimpflug principles. The purpose of this study is to check if they are interchangeable. METHODS Quantitative analysis evaluated data obtained from EyeSys and Pentacam, i.e. simulated keratometric values, in addition to flattest and steepest keratometric values. Sixty-three maps from each device (Eye...

هدف: انحنای قدامی قرنیه نقش مهمی در تشخیص و درمان کراتوکونوس دارد. هدف مطالعه­ ی حاضر تعیین تکرارپذیری انحنای قدامی 5 حلقه قرنیه (5-1 میلی ­متری از مرکز قرنیه) در بیماران کراتوکونوس با هریک از دستگاه­ های ارب اسکن و Eyesys و تعیین میزان توافق مقادیر انحنایی بین دو دستگاه می ­باشد. روش بررسی: در این مطالعه ، انحناهای قدامی 5 حلقه­ی قرنیه با ارب اسکن و Eyesys در 48 چشم را...

2012
Qinmei Wang Giacomo Savini Kenneth J. Hoffer Zhen Xu Yifan Feng Daizong Wen Yanjun Hua Feng Yang Chao Pan Jinhai Huang

PURPOSE To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices. METHODS Thirty-five eyes from 35 healthy subjects were included in the prospective study. In the first session, a single examiner performed on each subject randomly measurements with the RC-5000 (Tomey Corp., Japan), KR-8000 (Topcon, Japan), IOLMaster (Carl Zeiss Med...

2017
Alireza Baradaran-Rafii Sahba Fekri Mohammad Rezaie Shahram Salehi-Rad Ali Moradi Tahmineh Motevasseli Masumeh Kalantarion

PURPOSE To compare the corneal power measurements obtained using different topographic instruments after myopic photorefractive keratectomy (PRK). METHODS Patients with myopia who were candidates for corneal refractive surgery were sequentially included. Pre-PRK and six months post-PRK corneal powers were measured using Javal manual keratometer, Orbscan II, Galilei, Tomey TMS4, and EyeSys 200...

Journal: :The British journal of ophthalmology 2000
W A Douthwaite W T Evardson

AIMS To investigate the ability of a telecentric keratometer to describe the asphericity and curvature of convex ellipsoidal surfaces and human corneas. METHODS 22 conicoidal convex surfaces and 30 human corneas were examined by conventional keratometry. Additional keratometric measurements were made when the surface was tilted in the horizontal plane relative to the instrument optical axis. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید