background: in radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. in this study, the two available calculation algorithms of the varian eclipse 8.6 treatment planning system(tps), the anisotropic analytic algorithm (aaa) and pencil-beam convolution (pbc) was used to compare measured and calculated peripheral dose distributi...
background: the dosimetric performance of eclipse 6.5 three dimensional treatment planning system (3dtps) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of american association for physicists in medicine task group 53. materials and methods: the calculations were performed by the 3dtps for symmetric as well as asymmetric fields for standar...
A non-physical wedge generates a spatial dose distribution similar to that produced by a physical wedge without a physical filter in the photon beam. Instead, an exponential fluence profile is produced via motion of one of the collimating jaws. Proposed in the late 1970s, nonphysical wedges have been implemented on both Varian and Siemens’ accelerators as the Varian Dynamic Wedge (DW) and Sieme...
Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...
in this research, numerical simulation of a symmetric impact of a 2-d wedge, considering dynamic equations in two-phase flow is taken into account. the two-phase flow around the wedge is solved based on finite volume method and volume of fluid (vof) scheme. the dynamic mesh model is used to simulate dynamic motion of the wedge, thereby the effects of different dynamic meshes in both structured ...
In this research, numerical simulation of a symmetric impact of a 2-D wedge, considering dynamic equations in two-phase flow is taken into account. The two-phase flow around the wedge is solved based on finite volume method and volume of fluid (VOF) scheme. The dynamic mesh model is used to simulate dynamic motion of the wedge, thereby the effects of different dynamic meshes in both structured ...
background: it was intended to investigate the effect of physical wedge (pw) and enhanced dynamic wedges (edw) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. materials and methods: the varian’s clinac dual mode linear accelerator model 2100 c/d and siemen’s primus accelerators were used for radiation doses with 6 mv and ...
This research aimed to measure the received photon and thermal neutron doses to contralateral breast (CB) surface in breast cancer radiation therapy for different field sizes in presence of dynamic and physical wedges. The photon and thermal neutron doses were measured by thermo uminescent dosimeter (TLDs) chips for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes in presence of physical and dynamic ...