In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...

Contact resistance among the components of a polymer exchange membrane fuel cell (PEMFC) has a crucial effect on cell performance. The geometry of the endplate plays an essential role in the contact pressure distribution over the membrane electrode assembly (MEA) and the amount of contact resistance between plates. In this work, the effects of endplate geometry on the contact pressure distribut...

Journal: :Journal of Structural Engineering-asce 2022

Endplate moment connections with shape memory alloy (SMA) bolts provide self-centering for the seismic resilience of structures. Predicting response these new beam–column connections, which have not been codified yet, requires conducting experimental tests or detailed continuum finite-element simulations. Computationally efficient predictive tools are needed to facilitate analysis, design, and ...

Journal: :Journal of Constructional Steel Research 2021

The mechanical behavior of T-stubs bolted connection with two and four bolts per row under monotonic cyclic loading is analyzed in this paper using a 3D finite element model. aim the model that takes into account material geometrical nonlinearities to obtain evolution prying forces throughout cycles loading. numerical also used compare those row. results are prepared be as basis for proposing a...

Journal: :The Journal of General Physiology 1986
J H Caldwell D T Campbell K G Beam

The loose patch voltage clamp has been used to map Na current density along the length of snake and rat skeletal muscle fibers. Na currents have been recorded from (a) endplate membrane exposed by removal of the nerve terminal, (b) membrane near the endplate, (c) extrajunctional membrane far from both the endplate and the tendon, and (d) membrane near the tendon. Na current densities recorded d...

Journal: :Journal of biomechanical engineering 2013
Aakash Agarwal Vivek Palepu Anand K Agarwal Vijay K Goel Eda D Yildirim

In the thoracolumbar region, between 7% and 30% of spinal fusion failures are at risk for pseudarthrosis. From a biomechanical perspective, the nonconformity of the intervertebral graft to the endplate surface could contribute to pseudarthrosis, given suboptimal stress distributions. The objective of this study was to quantify the effect of endplate-graft conformation on endplate stress distrib...

Journal: :The Journal of General Physiology 1984
S M Vogel S Watanabe J Z Yeh J M Farley T Narahashi

Methyl- and ethylguanidine block the endplate current in frog muscle. Both derivatives blocked inward-going endplate currents without affecting outward endplate currents. Repetitive stimulation that evoked several inward endplate currents enhanced the block, which suggests that these agents interact with open endplate channels. The relative conductance vs. potential curve exhibited a transition...

2003

The loose patch voltage clamp has been used to map Na current density along the length of snake and rat skeletal muscle fibers . Na currents have been recorded from (a) endplate membrane exposed by removal of the nerve terminal, (b) membrane near the endplate, (c) extrajunctional membrane far from both the endplate and the tendon, and (d) membrane near the tendon . Na current densities recorded...