Background: Encrustation of urinary catheters is a frequent problem in patients with long-term indwelling catheters colonised with urease-positive bacteria such as Proteus mirabilis. Catheter blockage may follow catheter encrustation, potentially leading to systemic infection. Prevention of encrustation is difficult and avoidance of recurrence often unsuccessful. One possible preventative strat...
Ureteral stents and urethral catheters are commonly used medical devices for maintaining urinary flow. However, long-term placement (>30 days) of these devices in the urinary tracts is limited by the development of encrustation, a phenomenon that holds a prevalence of 50% within this patient population, resulting in a great deal of morbidity to the patients. Here we report the influence of surf...
A simple sensor has been developed to detect the early stages of urinary catheter encrustation and avoid the clinical crises induced by catheter blockage. In laboratory models of colonization by Proteus mirabilis, the sensor signaled encrustation at an average time of 43 h before catheters were blocked with crystalline biofilm.
OBJECTIVE The objective was to determine the incidence of bladder stones in patients with spinal cord injury (SCI) and to assess if catheter encrustation or positive urinary culture of Proteus mirabilis is predictive of bladder stones. BACKGROUND Bladder stones are common urological complication in those with SCI managed with indwelling urinary catheter. Detection and removal of bladder stone...
PURPOSE To evaluate the ability of heparin coating to inhibit Double J stent encrustation and compare it with the classic polyurethane Double J stent. PATIENTS AND METHODS The study involved five patients with bilateral obstructions, who required bilateral ureteral Double J stent placement. Every patient received a heparin-coated Double J stent and a traditional polyurethane Double J stent fo...
Ureteral stents and nephrostomy tubes have been used extensively in urology. Attendant to their use are their associated morbidities, such as pain, infection, and encrustation. We review the literature on the subject of the encrusted stents and drainage catheters, discuss the risk factors for encrustation, and describe the endourologic evaluation and management of these encrusted and retained u...
PURPOSE To present our experience and discuss the various endourological approaches for treating forgotten encrusted ureteral stents associated with stone formation. MATERIALS AND METHODS From July 2006 to December 2008, 14 patients (11 men and 3 women) with encrusted ureteral stents were analyzed. The average indwelling time of the stent was 4.9 years (range 1 to 12). Plain-film radiography ...
Clinical isolates of Proteus mirabilis causing catheter encrustation and blockage are susceptible to the biocide triclosan (MICs of 0.2 mg/liter). Studies with laboratory models of the bladder have demonstrated that the inflation of catheter retention balloons with triclosan solutions rather than water results in the diffusion of triclosan from the balloons into the surrounding urine and the in...
which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The author has reported the management of a large group of forgotten ureteral stents. The paper has a capacity to remind the complications of missed stents. The paper entitled " Combined Percutaneous and Transurethral Lithotripsy for Forgotten Ureteral Stents with Giant En...
INTRODUCTION Encrustation of urinary biomaterials is common; however, the incidence of surface deposition on the Vesair® intravesical pressure-attenuation balloon has not been previously reported. The purpose of this analysis is to determine the incidence and potential risk factors for encrustation of the Vesair intravesical balloon. METHODS The SOLECT trial is a prospective randomized contro...