آقامیری, سید محمود رضا, باغانی, حمیدرضا, حیدرلو, نعمت‌الله, مهدوی, سید ربیع,

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

آقامیری, محمودرضا , باغانی, حمیدرضا , حیدرلو, نعمت الله , مهدوی, ربیع ,

Background and purpose: Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation. Materials and methods: In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using...

Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...

Hamid Reza Baghani, Nematollah Heidarloo, Seyed Mahmoud Reza Aghamiri

Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...

2010
Alexander Nevelsky Zvi Bernstein Raquel Bar‐Deroma Abraham Kuten Itzhak Orion

The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead collimators. A telescopic device allows changing of source-to-surface distance (S...

E Akbari, H R Baghani H R Mirzaei K Tanha, M Mousavi, M Robatjazi, N Nafissi, S R Mahdavi,

Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...

Journal: :journal of biomedical physics and engineering 0
m robatjazi tehran university of medical sciences k tanha bushehr university of medical sciences s r mahdavi iran university of medical sciences h r baghani shahid beheshti university h r mirzaei shahid beheshti university of medical sciences m mousavi tehran university of medical sciences

background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated a...

2015
Mohamad M. Alabdoaburas Jean‐Pierre Mege Jean Chavaudra Jérémi Vũ Bezin Attila Veres Florent de Vathaire Dimitri Lefkopoulos Ibrahima Diallo

The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depth...

2001
Michael D. Mills Liliosa C. Fajardo David L. Wilson Jodi L. Daves William J. Spanos

Radiation performance characteristics of a dedicated intraoperative accelerator were determined to prepare the unit for clinical use. The linear accelerator uses standing wave X-band technology (wavelength approximately 3 centimeters) in order to minimize the mass of the accelerator. The injector design, smaller accelerator components, and low electron beam currents minimize radiation leakage. ...

Hojatollah Shahbazian Jafar Fatahiasl Mansour Zabihzadeh Mohammad Ali Behrooz Mohammad Javad Tahmasebibirgani Nahid Chegeni Reza Maskani

Introduction: Photon contamination is a restriction on treatment with electron that increase dose to healthy tissue below the tumor. The aim of this study is to reduce the photon contamination using a magnet system. Materials and Methods: A mini-applicator equipped with two neodymium boron permanent magnets was designed which make it possible to adjust the d...