نتایج جستجو برای: ebt3 gafchromic film

تعداد نتایج: 91000  

2017
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Atsushi Noguchi Kouichi Yabunaka

Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV)-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission int...

2016
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Kouichi Yabunaka

This study investigates an X-ray dose measurement method for computed tomography using Gafchromic films. Nonuniformity of the active layer is a major problem in Gafchromic films. In radiotherapy, nonuniformity error is reduced by applying the double-exposure technique, but this is impractical in diagnostic radiology because of the heel effect. Therefore, we propose replacing the X-rays in the d...

2015
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Kouichi Yabunaka

Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic ...

Journal: :Medical physics 2015
M Vadrucci G Esposito C Ronsivalle R Cherubini F Marracino R M Montereali L Picardi M Piccinini M Pimpinella M A Vincenti C De Angelis

PURPOSE To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. ...

2016
Farideh Farokhi Moghadam Hozan Mohammadi

Small photon field used in the intensity modulated radiotherapy (IMRT) and stereotactic radio surgery (SRS). It is difficult to measure beam profile and output factor because of electron disequilibrium, partial shutting of source because of this challenges, we need the good detector. This article is collection of 5 or more article and summary of the results of EBT3 that compared with EBT2 film ...

Journal: :Medical physics 2013
Joel Poder Stéphanie Corde

PURPOSE The purpose of this study was to measure the dose distributions for different Radiation Oncology Physics and Engineering Services, Australia (ROPES) type eye plaques loaded with I-125 (model 6711) seeds using GafChromic(®) EBT3 films, in order to verify the dose distributions in the Plaque Simulator™ (PS) ophthalmic 3D treatment planning system. The brachytherapy module of RADCALC(®) wa...

Journal: :Medical physics 2014
L Medina A Adrada M Filipuzzi E Garrigo C Venencia

PURPOSE The purpose of this paper is to characterize EBT3 using two types of scanner, analyzing the factors of influence of each dosimetry system. METHODS The film used in this study was GAFCHROMIC EBT3, the films were exposed at a dose range between 0Gy a 9Gy in a solid water phantom, SSD=100cm, 5cm depth and perpendicularly to the 6MV photon beam generated by a Novalis TX linear accelerator...

Background: Intensity modulated radiation therapy (IMRT) is an advanced method for delivery of three dimensional therapies, which provides optimal dose distribution with giving multiple nonuniform fluency to the patient. The complex dose distribution of IMRT should be checked to ensure that the accurate dose is delivered. Today, film dosimetry is a powerful tool for radiotherapy treatment Quali...

Journal: :Medical physics 2012
Thomas A D Brown Kenneth R Hogstrom Diane Alvarez Kenneth L Matthews Kyungmin Ham Joseph P Dugas

PURPOSE This work investigates the dose-response curves of GAFCHROMIC(®) EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. METHODS Monochromatic beams...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید