نتایج جستجو برای: ebt3

تعداد نتایج: 189  

2016
M.T. Bahreyni Toossi F. Khorshidi M. Ghorbani N. Mohamadian D. Davenport

BACKGROUND EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose wa...

2013
Valeria Casanova Borca Massimo Pasquino Giuliana Russo Pierangelo Grosso Domenico Cante Piera Sciacero Giuseppe Girelli Maria Rosa La Porta Santi Tofani

Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer configuration allows the user to eliminate side orientation dependence, which i...

2016
M.T. Bahreyni Toosi N. Mohamadian M. Ghorbani F. Khorshidi F. Akbari C. Knaup

OBJECTIVE Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer. METHODS A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT...

Journal: :journal of biomedical physics and engineering 0
m t bahreyni toossi medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran f khorshidi medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) m ghorbani medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) n mohamadian medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) d davenport comprehensive cancer centers of nevada, las vegas, nevada, usaسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

background: ebt and ebt3 radiochromic films have been used in radiotherapy dosimetry for years. objective: the aim of the current study is to compare ebt and ebt3 radiochromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. methods: calibrations of ebt and ebt3 films were performed with identical setups using a 6 mv photon beam of a siemens primus linac. skin dose was...

2016
Farideh Farokhi Moghadam Hozan Mohammadi

Small photon field used in the intensity modulated radiotherapy (IMRT) and stereotactic radio surgery (SRS). It is difficult to measure beam profile and output factor because of electron disequilibrium, partial shutting of source because of this challenges, we need the good detector. This article is collection of 5 or more article and summary of the results of EBT3 that compared with EBT2 film ...

Journal: :journal of biomedical physics and engineering 0
m t bahreyni toosi medical physics research center, mashhad university of medical sciences, mashhad, iran n mohammadian medical physics research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) m ghorbani medical physics research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) f khorshidi medical physics research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) f akbari medical physics department, reza radiation oncology center, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) c knaup comprehensive cancer centers of nevada, las vegas, nv, usa

objective: radiochromic ebt3 film is a later generation of radiochromic films. the aim of this study is to compare ebt and ebt3 radiochromic films in radiotherapy fields of breast cancer. methods: a rando phantom was irradiated by a 6 mv siemens primus linac with medial and lateral fields of radiotherapy of breast cancer. dosimetry was performed in various points in the fields using ebt and ebt...

Journal: :Medical physics 2015
M Vadrucci G Esposito C Ronsivalle R Cherubini F Marracino R M Montereali L Picardi M Piccinini M Pimpinella M A Vincenti C De Angelis

PURPOSE To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. ...

Journal: :Medical physics 2012
T Inoue S Sugimoto K Fukata C Kurokawa S Ozawa K Sasai

PURPOSE To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams were 9 and 12 MeV. The irradiated field size was 10×10 cm2 and the source to ...

Journal: :Medical physics 2014
L Medina A Adrada M Filipuzzi E Garrigo C Venencia

PURPOSE The purpose of this paper is to characterize EBT3 using two types of scanner, analyzing the factors of influence of each dosimetry system. METHODS The film used in this study was GAFCHROMIC EBT3, the films were exposed at a dose range between 0Gy a 9Gy in a solid water phantom, SSD=100cm, 5cm depth and perpendicularly to the 6MV photon beam generated by a Novalis TX linear accelerator...

2014
J. Eduardo Villarreal‐Barajas Rao F.H. Khan

The objective of this study is to evaluate the suitability of recently introduced radiochromic film EBT3 for clinical dosimetry in the kilovoltage (kV) range. For this purpose, a kV X-ray irradiator, X RAD 320ix in the range 70 to 300 kVp, a clinical 60Co source, a 6 MV and an 18 MV X-ray clinical beam from a Varian linear accelerator were calibrated following AAPM dosimetry protocols. EBT3 fil...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید