نتایج جستجو برای: dosimetry verification
تعداد نتایج: 83031 فیلتر نتایج به سال:
abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was als...
Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of patient positioning for radiotherapy in recent decades. Since EPID images contain dose information, many groups have investigated their use for radiotherapy dose measurement. With the introduction of the amorphous-silicon EPIDs, the interest in EPID dosimetry has been accelerated because of the favourabl...
The purpose of this study was to develop dosimetry verification procedures for volumetric-modulated arc therapy (VMAT)-based total marrow irradiation (TMI). The VMAT based TMI plans were generated for three patients: one child and two adults. The planning target volume (PTV) was defined as bony skeleton, from head to mid-femur, with a 3 mm margin. The plan strategy similar to published studies ...
AIM To evolve a fast dose verification method for high-dose-rate (HDR) brachytherapy treatment plans and to demonstrate its applicability in different clinical cases. MATERIALS AND METHODS We developed a software tool in VC++ for the Varisource HDR unit for HDR dosimetry plan verification using TG-43 parameters. HDR treatment dosimetry of a number clinical cases using Varisource was verified ...
A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation Oldham Mark; Thomas Andrew; O'Daniel Jennifer; Juang Titania; Ibbott Geoffrey; Adamovics John; Kirkpatrick John P International journal of radiation oncology, biology, physics (2012), 84(2), 540-6. PURPOSE: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehe...
Many important dosimetry audit networks for radiotherapy have their roots in clinical trial quality assurance (QA). In both scenarios it is essential to test two issues: does the treatment plan conform with the clinical requirements and is the plan a reasonable representation of what is actually delivered to a patient throughout their course of treatment. Part of a sound quality program would b...
In this paper the various approaches of EPID-based in vivo IMRT and VMAT dose verification, and their clinical implementation, are described. It will be shown that EPID-based in vivo dosimetry plays an important role in the total chain of verification procedures in a radiotherapy department. EPID-based dosimetry, in combination with in-room imaging, is a fast and accurate tool for 3D in vivo ve...
introduction dosimetric accuracy is a major issue in the quality assurance (qa) program for treatment planning systems (tps). an important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. in brachytherapy (bt) of gynecological (gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید