نتایج جستجو برای: dosimetery
تعداد نتایج: 19 فیلتر نتایج به سال:
background: indoor radon gas (222rn) has been recognized as one of the health hazards for human. air radon comes mainly from basement soil and construction materials. saghand region with rich uranium mines lies 180 km from yazd, so the indoor radon concentration can be high. yazd, with population of about 457000, is the biggest city near saghand, thus, indoor gamma background radiation of yazd ...
Photodynamic therapy dosimetery and treatment planning is affected by the concentration of photosensitizer in a given tissue, and these values are often estimated based on measurements of fluorescence in the region to be treated. Some studies with benzoporphyrin derivate monoacid ring a (BPD-MA) showed a significant increase in fluorescence quantum yield with deoxygenation of the solution, indi...
Background: During breast three fields radiotherapy, the problem is that the divergency of the field interferes with matching the edges. So the matching point of these supraclav and tangential field will suffer from over-dose and under-dose. To prevent these these divergency, a half- block is often applied at supracluv field. Also in some techniques like collimator and couch rotation, corner bl...
INTRODUCTION In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions. MATERIALS AND METHODS All measurements were performed for 60Co γ-ray beams and...
Introduction: Ionizing radiations are one of the harmful factors in workplaces, so this study aimed to determine the radiation protection condition in radiology centers in educational hospitals of Ahwaz University of medical sciences. Methods and Materials: This research was a cross-sectional study that was performed among 25 active radiology rooms in 2013. First, an expert visits the radiolog...
background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...
normal 0 false false false en-us x-none fa introduction: in radiation therapy centers across iran, protection of normal tissues is usually accomplished by either cerrobend or lead block shielding. in this study, the influence of these two shielding methods on central axis dose distribution of photon beam a cobalt unit was investigated in clinical conditions. materials and methods: all measureme...
Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید