نتایج جستجو برای: dose verification

تعداد نتایج: 384124  

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak

abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was als...

Farzaneh Allaveisi Nasrin Amini

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

Journal: :Radiotherapy and Oncology 2016

Journal: :iranian journal of medical physics 0
micaeil mollazadeh m.sc. student in medical physics, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. mahmood allahverdi associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. tayyeb allahverdi pourfallah assistant professor, biochemistry and biophysics dept., mazandaran university of medical sciences, sari, iran. nader riahi alam associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran. mohammadreza ay associate professor, medical physics and engineering dept., tehran university of medical sciences, tehran, iran.

introduction: gafchromic ebt films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (tpss). their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. this study was designed to evaluate the dosimetric parameters of...

B. Li, G. Xu, H. Jiang, H. Wang, L. Liu, Z. Xiong,

Background: The dynamic phantom is one of the best tools to study the impact of motion on tumor target delineation and absorbed dose verification during dose delivery. Materials and Methods: this study, a 6-DOF (degrees of freedom) phantom was designed following the stacked serial kinematics and assembled by six commercial motion stages to generate 6-DOF motion, which were RotX (pitch, around X...

Journal: :Journal of Medical Physics 2009

Ahmad Mostaar, Golbarg esmailie Hassan Nedaei Mohammad Amin Mosleh Shirazi Seied Rabi Mahdavi, Vahideh Nazari

Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context.   Materials and Methods: In this study, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید