نتایج جستجو برای: dose profile
تعداد نتایج: 520949 فیلتر نتایج به سال:
ct.scan examinations cause high patient absorbed dose from x-ray ionizing radiation. therefore it is necessary to obtain superficial dose profile in z-line. in this research 11 thermoluminecent dosimeter (tld), after calibration were located on z line perpendicular to slice thickness. ct.scan machines did x-ray exposures. the resultant dose profiles showed gussian shape apperience, which has se...
introduction polymer gel dosimeters offer a practical solution to 3d dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. in this study, egsnrc calculated and pagat polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of gamma knife in homogeneous and inhomogeneous phantoms were compared with eac...
background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
Introduction: Radiation therapy using electron beams is a promising method due to its physical dose distribution. Monte Carlo (MC) code is the best and most accurate technique for forespeaking the distribution of dose in radiation treatment of patients.Materials and Methods: We report an MC simulation of a linac head and depth dose on central axis, along with profile calculations. The purpose o...
Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...
In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...
background: the assessment of rbe quantity in the treatment of cancer tumors with proton beams in treatment planning systems (tps) is of high significance. given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1. objective: the main objective of this study was to assess rbe quantity of proton beams and their variations...
Background: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical properties of 18 MV photon...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید