نتایج جستجو برای: dose linearity
تعداد نتایج: 325658 فیلتر نتایج به سال:
background: we have validated the monitor unit calculations from a commercially available treatment planning system (tps) for three intensity modulated radiotherapy (imrt) planning techniques for tangential breast irradiation by using ionization chamber measurements. materials and methods: treatment plans were generated for forty-two breast patients by a forward planned field in field technique...
background: drug resistance is widely believed to be an increasingly serious threat to global public health. we have previously reported that short term exposure of microorganisms to diagnostic ultrasound waves could significantly alter their sensitivity to antibiotics. in our previous studies, klebsiella pneumoniae showed major differences in the sensitivity to antibiotics in exposed and non-e...
some areas of ramsar, a city in northern iran are among the world’s wellknown inhabited areas with highest levels of natural radiation. annual exposure levels in these areas are up to 260 mgy y‐1 and the mean exposure rate is about 10 mgy y‐1 for a population of about 2000 residents. if elevated levels of natural radiation as high as a few hundred msv per year is detrimental to health and leads...
background: in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...
As a basis for establishing radiation protection standards, a substantial amount of quantitative information is now available on the frequency with which malignant diseases are induced in man by moderately high doses of radiation. Such estimates can now be made not only for irradiation of the whole body but also for exposure of a number of body organs individually. The frequency with which canc...
The problem for assessment of dose proportionality (or linearity) is studied. Various methods for assessment of dose proportionality (or linearity) such as ANOVA type F-test have been proposed. Cheng et al. (2006) proposed an alternative approach based on the slopes of adjacent dose levels under a crossover design. They showed that when dose proportionality (or linearity) cannot be established,...
Background: In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید