نتایج جستجو برای: distal radius fractures

تعداد نتایج: 167915  

Journal: :anesthesiology and pain medicine 0
ali tabrizi orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran; orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran. tel: +98-9143130829 fardin mirza tolouei orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran ebrahim hassani department of anesthesiology, imam khomeini hospital, urmia university of medical sciences, urmia, iran hassan taleb orthopedics surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iran asghar elmi orthopedics surgery department, shohada educational hospital, tabriz university of medical sciences, tabriz, iran

conclusions hematoma block analgesia used in distal radius fractures of the elderly is a very safe and effective method that seems preferable to general anesthesia in emergency departments. objectives the aim of this study was to compare two analgesia methods including hematoma block and general anesthesia in people over 60 years in the orthopedic emergency department. methods 68 elderly patien...

Journal: :the archives of bone and joint surgery 0
mohsen mardani-kivi guilan road trauma research center, school of medicine, guilan university of medical sciences, rasht, iran behzad zohrevandi guilan road trauma research center, school of medicine, guilan university of medical sciences, rasht, iran khashayar saheb-ekhtiari guilan road trauma research center, school of medicine, guilan university of medical sciences, rasht, iran keyvan hashemi-motlagh guilan road trauma research center, school of medicine, guilan university of medical sciences, rasht, iran

background: considering the importance of an early diagnosis and proper decision-making in regards to the treatment of pediatric distal radius and elbow fractures, this study examines emergency medicine specialists’ accuracy in the diagnosis and treatment of these patients. methods: from 2012 and 2013, children less than 14 years old who were referred to an academic hospital emergency departmen...

  Background: Considering the importance of an early diagnosis and proper decision-making in regards to the treatment of pediatric distal radius and elbow fractures, this study examines emergency medicine specialists’ accuracy in the diagnosis and treatment of these patients. Methods: From 2012 and 2013, children less than 14 years old who were referred to an academic hospital emergency departm...

Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...

Background: Distal radius fractures constitute 17% of all fractures and 75% of forearm fractures in adults. Due to the vital role of the hands in a wide range of daily tasks, quick recovery and fewer complications for the patients are important. The purpose of this study was to compare the two common treatments of distal radius fractures namely, percutaneous pinning and pin-in-plaster. Methods...

Journal: :archives of trauma research 0
sascha rausch department of traumatology, hand and reconstructive surgery, friedrich-schiller-universität jena, germany +49-3641322889, [email protected]; department of traumatology, hand and reconstructive surgery. friedrich-schiller-universität jena, jena, germany. tel.: +49-3641322889, fax: +49-36419322802 kajetan klos department of traumatology, hand and reconstructive surgery, friedrich-schiller-universität jena, germany +49-3641322889, [email protected] florian gras department of traumatology, hand and reconstructive surgery, friedrich-schiller-universität jena, germany +49-3641322889, [email protected] hristo kostov skulev arbeitsgemeinschaft für osteosynthesefragen, switzerland albrecht popp technical university of varna, bulgaria gunther olaf hofmann department of traumatology, hand and reconstructive surgery, friedrich-schiller-universität jena, germany +49-3641322889, [email protected]

conclusions the outside diameter/inside diameter ratio at the metaphyseal/diaphyseal junction of the distal radius on ap radiographs is suitable for use as a predictor of distal-radius bone density. further studies should be performed, and clinical utility evaluated. results the mean bmd was 0.559 (sd = 0.236) g / cm2. the mean outside diameter/inside diameter ratio was 1.24 (sd = 0.013); the r...

Journal: :emergency journal 0
anita sabzghabaei emergency department, loghman hakim hospital, shahid beheshti university of medical sciences, tehran, iran. majid shojaee emergency department, imam hossein hospital, shahid beheshti university of medical sciences, tehran, iran. ali arhami dolatabadi emergency department, imam hossein hospital, shahid beheshti university of medical sciences, tehran, iran. mohammad manouchehrifar emergency department, loghman hakim hospital, shahid beheshti university of medical sciences, tehran, iran. mahdi asadi emergency department, imam hossein hospital, shahid beheshti university of medical sciences, tehran, iran.

introduction: distal radius fractures are a common traumatic injury, particularly in the elderly population. in the present study we examined the effectiveness of ultrasound guidance in the reduction of distal radius fractures in adult patients presenting to emergency department (ed). methods: in this prospective case control study, eligible patients were adults older than 18 years who presente...

F Eslamiyan J Ganjpour J Soleimanpour M GHorbanzadeh

Background & Aims: Metaphysical distal radius fractures are common fractures account for almost half of the fractures in Orthopaedic Emergencies. According to different studies, 1-6 weeks cast immobilization after distal radius surgery has been recommended. The aim of this study was to compare outcomes and complications of short-term and long-term immobilization treatment methods. Methods: In a...

Journal: :archives of trauma research 0
kavin khatri department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india; department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india. tel: +91-8743878077 vijay sharma department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india kamran farooque department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india vivek tiwari department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india

conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...

Journal: :trauma monthly 0
mohammad hossein karimi nasab department of orthopedics,orthopedic research center, mazandaran university of medical sciences, sari, ir iran masoud shayesteh azar department of orthopedics,orthopedic research center, mazandaran university of medical sciences, sari, ir iran; department of orthopedics, mazandaran university of medical sciences, sari, ir iran. tel: +98-9111515654, fax: +98-1133377169 samira fazel moghaddam faculty of medicine, mazandaran university of medical sciences, sari, ir iran mehrdad taghipour nephrology and urology research center, baqiyatallah university of medical sciences, tehran, ir iran

results overall, ≥ 2 mm shortening of the radius was seen in 28% of the patients, 53% had 2 - 5 mm radial shortening and 19% of the patients had more than 5 mm shortening of the radius. most of the participants had acceptable outcomes. the mean angulation was 6.28 ± 2.85 degrees and the mean shortening was 3.92 ± 2.22. thirty-nine percent of the patients had an angulation of less than 5 mm, 56%...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید