نتایج جستجو برای: dimethylglyoxime
تعداد نتایج: 122 فیلتر نتایج به سال:
We describe a technique for determining nickel in serum by flameless atomic absorption, with use of dimethylglyoxime. The procedure permits a greater number of analyses per technician at a relatively low cost, yet provides acceptable accuracy and reliability. After the sample is evaporated and dry ashed in a muffle furnace at 560 degrees C for 5 h, the residual salts are dissolved in hydrochl...
Nickel oxide nanotubes with great antibacterial activities, electrochemical capacitance, and magnetic properties have been synthesized through a precursor method with dimethylglyoxime as precipitant for the precursor, and the method has been developed for the synthesis of Ni/C nanorods.
The chelating agents EDTA, o-phenanthroline, nitrilotriacetic acid (NTA), ethylenediamine-bis(o-hydroxyphenylacetic acid) (EDDA) or dimethylglyoxime prevented the expression of hydrogenase activity in batch cultures of nitrogen-fixing Azotobacter chroococcum, but did not inhibit preformed enzyme. The inhibition was reversed either by adding a mixture of trace elements (Cu2+, Mn2+, Zn2+, Co2+) o...
Aryl-substituted tetraimine complexes related to Co(dmgBF(2))(2)(MeCN)(2) (dmg = dimethylglyoxime) were synthesized and are active for hydrogen evolution. Co(dmgBF(2))(2)(MeCN)(2) can be adsorbed to a glassy carbon electrode. The chemically modified electrode is active for hydrogen evolution in aqueous solution at pH < 4.5, with an overpotential of only 100 mV.
BACKGROUND In April 2014, the European Chemicals Agency defined the concept of 'prolonged contact with skin' as used in the EU nickel restriction. OBJECTIVES To establish a baseline of nickel-releasing items on the Swedish market conforming with the EU nickel restriction according to the definition of 'prolonged contact' with the skin. METHODS We performed a limited market survey in Stockho...
Differentiai pulse cathodic stripping voltammetry can be applied to sea water with high sensitivity for nickel and cobalt analysis (limits of detection about 0.005 and 0.002 j.lg L 1 respectively) using the dimethylglyoxime complexes. At concentrations of 0.200 j.lg Ni L -l and 0.050 j.lg Co L 1 the standard deviations for replicate analyses were 8% and 2% respectively. The linearity of the cal...
Post synthetically-modified UiO-66-NH 2 with a molecular cobaloxime [Co(DMG) Cl ] (DMG = dimethylglyoxime) catalyst displays excellent photo-(404 μmol g −1 h ) and electrocatalytic H evolution activity in an aqueous solution.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید