نتایج جستجو برای: digital x

تعداد نتایج: 916179  

Journal: :iranian endodontic journal 0
mohammad mahdi aghdasi associate professor of radiology, dental school, shahid beheshti university of medical science mohammad asnaashari 2. associate professor of endodontics, dental school, shahid beheshti university of medical science, tehran, iran alireza aliari 3. dental student, dental research center, shahid beheshti university of medical sciences, tehran, iran farahnaz fahimipour 3. dental student, dental research center, shahid beheshti university of medical sciences, tehran, iran sepideh soheilifar 3. dental student, dental research center, shahid beheshti university of medical sciences, tehran, iran

introduction: inappropriate condensation of gutta-percha or improper use of sealer can lead to voids in root canal filling material and consequent failure of the treatment. timely detection of voids within root canal filling may prevent complications. in this study, we compared the accuracy of digital and conventional radiograph for detecting voids within root canal fillings . materials & metho...

Journal: :the archives of bone and joint surgery 0
andrewj. miller department of orthopaedics, thomas jefferson university hospital, philadelphia, usa christopher jones department of orthopaedics, thomas jefferson university hospital, philadelphia, usa frederick liss department of orthopaedics, thomas jefferson university hospital, philadelphia, usa jack abboudi department of orthopaedics, thomas jefferson university hospital, philadelphia, usa william kirkpatrick department of orthopaedics, thomas jefferson university hospital, philadelphia, usa pedro beredjiklian department of orthopaedics, thomas jefferson university hospital, philadelphia, usa

object: the gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (dexa).  prior studies have shown poor reliability using analog wrist x-rays in diagnosing osteoporosis. our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand x-rays in osteoporosis screening. we hypothesized that similar to analog counterparts, dig...

Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA).  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, dig...

Journal: :iranian journal of public health 0
masoud dehghan tezerjani reza maroofian mohammad yahya vahidi mehrjardi barry a. chioza shiva zamaninejad seyed mehdi kalantar

oral-facial-digital syndrome as heterogeneous developmental conditions is characterized by abnormalities in the oral cavity, facial features and digits. furthermore, central nervous system (cns) abnormalities can also be part of this developmental disorder. at least 13 forms of ofds based on their pattern of signs and symptoms have been identified so far.  type 1 which is now considered to be a...

  Background and purpose: The radiographic imaging repeat rate (RR) in digital and conventional imaging systems is considered as a quality control indicator. RR increases the unnecessary patient and staff dose, prevents the loss of resources and depreciation of systems and increases the time for radiographic services. In this study, digital radiographic RR and its related factors were inv...

Journal: :iranian journal of radiation research 0
r. paydar medical physics and biomedical engineering department, school of medicine, tehran university of medical sciences, tehran, iran a. takavar medical physics and biomedical engineering department, school of medicine, tehran university of medical sciences, tehran, iran m.r. kardan nuclear sciences research school, radiation applications research school, tehran, iran a. babakhani national radiation protection department, iranian nuclear regulatory authority, teheran iran m.r. deevband national radiation protection department, iranian nuclear regulatory authority, teheran iran s. saber pulmonary ward, shariati hospital, school of medicine, tehran university of medical sciences, tehran, iran

background: the radiation doses resulting from diagnostic x-ray examinations are routinely measured in terms of entrance surface dose (esd) and effective dose (ed). in this study, for the purpose of radiation protection, the radiation doses received from digital chest x-ray examination were evaluated in terms of esd and ed. material and methods: the ed was calculated by using the mcnp monte car...

Journal: :iranian journal of radiology 0
hui-zhao wu department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china mahrukh latif department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china zhi-wei zhong department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china bao-hai yu department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china wen-juan wu department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china; department of radiology, the third hospital of hebei medical university, no.139, ziqiang road, shijiazhuang, 050051, china. tel: +86-31188603366, fax: +86-31187023626 feng zhang department of rehabilitation medicine, the third hospital of hebei medical university, shijiazhuang, china

conclusion dt-sfp can improve the detection of relatively early bone abnormalities in acetabular and proximal femur compared with conventional radiography. dt-sfp can also observe the abnormal impact between acetabular and proximal femur. patients and methods ninety-four consecutive patients with discomfort around the hip joint underwent dt-sfp and conventional radiography. the imaging features...

ثبوتی , فرهاد, غفاری, روشنک, فیض بخش, مسعود, اصلانی, فرزین, عمرانی, علی رضا,

Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...

A. Babakhani, A. Takavar, M.R. Deevband, M.R. Kardan, R. Paydar, S. Saber,

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

ژورنال: :مجله دانشگاه علوم پزشکی مازندران 0
فرزین اصلانی farzin aslani علوم پزشکی مازندران علی رضا عمرانی alireza omrani علوم پزشکی مازندران مسعود فیض بخش masud feyzbakhsh علوم پزشکی مازندران روشنک غفاری roshanak ghafari علوم پزشکی مازندران فرهاد ثبوتی farhad sobuti علوم پزشکی مازندران

background and purpose: digital radiography has led to many improvements in radiology. despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. the aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید