نتایج جستجو برای: differential transformer

تعداد نتایج: 295999  

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...

In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...

A. A. Abdoos A. Ebadi S. M. Hosseini,

The restricted earth fault (REF) relay is a type of differential protection which is used for detection of internal ground faults of power transformers. But, during external faults and transformer energization conditions, the probability of current transformer (CT) saturation increases. Thus, the spurious differential current due to CT saturation, can lead to REF relay maloperation. In this pap...

2007
Zoran Gajić

This thesis describes how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard transformer differential protection for such applications is considered impossible in ...

Low- impedance transformer ground differential relay is a part of power transformer protection system that is employed for detecting the internal earth faults. This is a fast and sensitive relay, but during some external faults and inrush current conditions, may be exposed to maloperation due to current transformer (CT) saturation. In this paper, a new intelligent transformer ground differentia...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه مازندران 1387

چکیده ندارد.

In this paper, a new method has been presented for differential protection of power transformers.  In this approach, chaotic method has been used for distinguishing of inrush current from internal fault current of the transformer. The proposed algorithm has been designed based on analysis of harmonic components of the differential current of the transformer due to internal faults and inrus...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تهران 1387

چکیده ندارد.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید