نتایج جستجو برای: dibenzo 15 crown 5
تعداد نتایج: 1573549 فیلتر نتایج به سال:
In a three-component system containing dibenzo-24-crown-8 (1), diamino-dibenzo-24-crown-8 (2), and 1,2-bis(4,4(')-dipyridyl)ethane (3(2+)), axle 3(2+) can shuttle between wheels 1 and 2 by acid-base control, accompanying color changes from yellow to red. This system could not only be taken as a chromophoric supramolecular switch, but also exhibit a function as INHIBIT logic gate.
Stability constants in 90% (v/v) DMSO /water mixture were evaluated for the complexes of Ag(I), Co(II), Cu(II), Mn(II), Ni(II), Zn(II), Pb(II), Cr(III) and Fe(III) with the macrocyclic compounds, namely, 15-crown-5, benzo-15-crown-5, 18-crown-6, dibenzo18-crown-6, dicyclohexano-18-crown-6, dibenzo-24-crown-8 and dicyclohexano-24-crown-8 by conductometric titrations. A potentiometric study of co...
The various association constants, bnm and Knm, of NaCl and NaClO4 with [12]crown-4, [15]crown-5, [18]crown-6, benzo[15]crown-5, benzo[12]crown-4, dibenzo[18]crown-6 and dinaphtho[18]crown-6 have been estimated in a mixture of dioxane/water (80/20) using a sodium ion selective electrode (ISE). The constants have been estimated using 1=ðKnm1⁄2Lo n1m21Þ5 ð1 2 nP 0Þn ð1 2 mP 0Þm=P 0; where P 0, th...
The interaction between benzo-15-crown-5 (B15C5), dibenzo-18-crown-6 (DB18C6), dibenzyl-daza-18crown-6 (DBzDA18C6), N-phenyl-aza-15-crown-5 (NPhA15C5) and dibenzopyridine-18-crown-6 (DBPy18C6) with π-acceptor 2,3-dichloro-5,6-dicyanobenzoquinone (DDQ) in chloroform solution was studied spectrophotometrically. The interaction of B15C5-DDQ and DB18C6-DDQ caused the formation...
the interaction between benzo-15-crown-5 (b15c5), dibenzo-18-crown-6 (db18c6), dibenzyl-daza-18crown-6 (dbzda18c6), n-phenyl-aza-15-crown-5 (npha15c5) and dibenzopyridine-18-crown-6 (dbpy18c6) with π-acceptor 2,3-dichloro-5,6-dicyanobenzoquinone (ddq) in chloroform solution was studied spectrophotometrically. the interaction of b15c5-ddq and db18c6-ddq caused the formation of 1:1 charge transfe...
The feasibility of fabricating copper-sensitive chemically modified electrodes (CMEs) for trace analysis in aqueous and in 40% (v/v) ethanol-water media was investigated. Carbon paste electrodes modified with crown ethers were constructed by mixing the crown ethers into a graphite powder-paraffin oil matrix. The electrodes so formed were able to bind Cu(II) ions chemically and gave better volta...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید