Journal: :trauma monthly 0
younis kamal postgraduate department of orthopaedics, government medical college (gmc) srinagar, srinagar, india; postgraduate department of orthopaedics, government medical college (gmc) srinagar, srinagar, india. tel: +91-9906966960 hayat ahmad khan postgraduate department of orthopaedics, government medical college (gmc) srinagar, srinagar, india naseemul gani postgraduate department of orthopaedics, government medical college (gmc) srinagar, srinagar, india anil gupta postgraduate department of orthopedics, government medical collage jammu, university of jammu, jammu, india dara singh postgraduate department of orthopedics, government medical collage jammu, university of jammu, jammu, india snobar gul postgraduate department of anatomy, government medical college srinagar, kashmir university, srinagar, india

conclusions managing such patients needs a proper transport facility, proper care during transport, appropriate evaluation in the hospital and prompt conservative or operative treatment. treatment is usually safe and effective by well trained professionals with good clinical and radiological outcomes. patients and methods thirty patients (22 males, 8 females) with upper cervical spine injuries ...

Journal: :Dental materials journal 2015
Takashi Nakamura Tsuyoshi Sugano Hirofumi Usami Kazumichi Wakabayashi Hiroshi Ohnishi Tohru Sekino Hirofumi Yatani

The purpose of this study is to evaluate the fitting accuracy and fracture resistance of crowns using a hybrid zirconia frame made of both porous and dense zirconia. Commercial semi-sintered zirconia, sintered dense zirconia and sintered hybrid zirconia were used. Sintered zirconia was milled using the CAD/CAM system, and semi-sintered zirconia was milled and sintered to fabricate molar crown f...

Journal: :Bone 2011
Grethe Jonasson Valter Sundh Margareta Ahlqwist Magnus Hakeberg Cecilia Björkelund Lauren Lissner

Bone structure is the key to the understanding of fracture risk. The hypothesis tested in this prospective study is that dense mandibular trabeculation predicts low fracture risk, whereas sparse trabeculation is predictive of high fracture risk. Out of 731 women from the Prospective Population Study of Women in Gothenburg with dental examinations at baseline 1968, 222 had their first fracture i...

Journal: :The International journal of oral & maxillofacial implants 2016
Yara K Hosein Angie Smith Cynthia E Dunning Ali Tassi

PURPOSE Fracture of orthodontic mini-implants during insertion is a limiting factor for their clinical success. The purpose of this study was to determine the fracture potential of commonly used self-drilling orthodontic mini-implants when placed into simulated thick, dense mandibular bone. MATERIALS AND METHODS Six mini-implant systems were assessed for the potential for fracture (Aarhus, Me...

محمدحسین فتحی, , مهشید خرازیها, ,

In this study, forsterite nanopowder was prepared by mechanical alloying and post-heat treatment method. Bioactive properties of forsterite nanopowder were studied by immersing the powder in the SBF. Nanostructure forsterite bulk dense form was prepared by the two step sintering method. It was found that pure forsterite nanopowder with 25-60nm particle size was produced. The results of soaking ...

M. Kalantar and G. Fantozzi,

Dense Silicon nitride was investigated to determine the effect of its microstructural parameters and densification on thermo-mechanical properties and thermal stress resistance to fracture initiation during a hot or cold mechanical and thermal shock testing. The different materials and microstructures were obtained by changing the parameters such as the type of the powder, additive, forming p...

M. Kalantar and G. Fantozzi,

Dense Silicon nitride was investigated to determine the effect of its microstructural parameters and densification on thermo-mechanical properties and thermal stress resistance to fracture initiation during a hot or cold mechanical and thermal shock testing. The different materials and microstructures were obtained by changing the parameters such as the type of the powder, additive, forming p...

2014
Renata de Faria Santos Antonio Carlos de Oliveira Ruellas Daniel Jogaib Fernandes Carlos Nelson Elias

OBJECTIVE This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. METHODS Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal n...

2010
Tommy Y. Kim Maria H. Lin Lilit Minasyan William N. Holmes Ameer P. Mody

218 Volume XI, no. 2 : May 2010 computed tomography (CT) showed a small nondisplaced fracture of the orbital roof with a fracture around the orbital apex. There was loculated air and hemorrhage within the left orbit, but the globe was intact. There was also an abnormal dense intracranial calcification along the lateral margin of Tommy Y. Kim, MD* Ұ Maria H. Lin, MD† Lilit Minasyan, MD* William ...