The CT scanner-displayed radiation dose information is based on CT dose index (CTDI) over an integration length of 100 mm (CTDI(100)), which is lower than the CTDI over an infinite integration length (CTDI(∞)). In an adult or a pediatric body CT scan, the limiting equilibrium dose can be established near the central scan plane, and CTDI(∞) more closely indicates the accumulated dose than CTDI(1...
Dosimetry in kilovoltage cone beam computed tomography (CBCT) is a challenge due to the limitation of physical measurements. To address this, we used a Monte Carlo (MC) method to estimate the CT dose index (CTDI) and the dose length product (DLP) for a commercial CBCT system. As Dixon and Boone showed that CTDI concept can be applicable to both CBCT and conventional CT, we evaluated weighted CT...
PURPOSE The aim of this study was to assess the distribution of CT dose index (CTDI) values reported by sites undergoing ACR CT accreditation between 2002 and 2004. METHODS Weighted CTDI (CTDI(w)) values were measured and reported by sites applying for ACR CT accreditation, and the percentage of scanners with values above the 2002 ACR diagnostic reference levels (DRLs) was determined. Acquisi...
Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...
A straightforward method is presented to estimate peak skin doses (PSDs) delivered by computed tomography (CT) scanners. The measured PSD values are related to the well-known volume CT dose index (CTDI(vol)), displayed on the console of CT scanners. PSD measurement estimates were obtained, in four CT units, by placing radiochromic film on the surface of a CTDI head phantom. Six different X-ray ...
In x-ray computed tomography (CT), the most common parameter used to estimate and minimize patient dose is the CT dose index (CTDI). The CTDI is a volume-averaged measure that is used in situations where the table is incremented in conjunction with the tube rotation. Variants of the CTDI correct for averaging across the field of view and for adjacent beam overlaps or gaps. CTDI is usually measu...
PURPOSE To determine relationships among patient size, scanner radiation output, and size-specific dose estimates (SSDEs) for adults who underwent computed tomography (CT) of the torso. MATERIALS AND METHODS Informed consent was waived for this institutional review board-approved study of existing data from 545 adult patients (322 men, 223 women) who underwent clinically indicated CT of the t...
INTRODUCTION The purpose of the present study was to evaluate the influence of different variables on radiation dose and image quality based on a national database. MATERIALS AND METHODS Taiwan's Ministry of Health and Welfare requested all radiology departments to complete a questionnaire for each of their CT scanners. Information gathered included all scanning parameters for CT head scans. ...
BACKGROUND AND PURPOSE Since the introduction of flat panel detector-equipped C-arms, the use of flat panel detector CT (FPCT) in the neuroradiologic angiography suite has become more frequent. This examination implicates its own specific radiation exposure. We used the CT dose index (CTDI) concept and adapted it to the special FPCT geometry to provide a consistent comparison with multisection ...