نتایج جستجو برای: corrugated tube

تعداد نتایج: 99418  

Journal: :The Veterinary record 1985
R G Douglas

The affected pig should be restrained and the corrugated tube gently inserted into the lumen of the prolapsed rectum the halfway-point on the tube needs to be inserted as far as the anal sphincter. The rubber bands should be stretched over the prolapse and placed as near as possible to the perianal skin; they must be tight enough to stop the blood supply to the prolapse. Faeces may move down th...

Turbulent heat transfer in Helically Corrugated Tubes (HCT) was numerically investigated for pure water and SiO2 nanofluid using Computational Fluid Dynamics (CFD). This study was carried out for different corrugating pitches (5, 7, 8 mm) and heights (0.5, 0.75, 1.25 mm) at various Reynolds numbers ranging from 5000 to 13300. The effect of nanoparticles on heat transfer augmentation for plain t...

Journal: :international journal of energy and environmental engineering 2011
s hossainpour r hassanzadeh

this paper presents a three-dimensional numerical investigation carried out in turbulent forced convection in a tube with helical ribs. enhancement of heat transfer using helically corrugated tubes has beenstudied experimentally by many researchers but there exist a few published numerical analyses results. the paper also introduces the results of heat transfer and friction factor data for inco...

2016
S. Prabakaran

In present work, comparison of three different tube bundles for particular heat exchanger is proposed. Three types are smooth, micro finned and corrugated tubes. Heat exchanger will be designed with smooth tube bundle and simulated. Micro fin and corrugation over tube is applied separately for same heat exchanger in feasible size and simulated for performance. Besides, comparison is done with h...

2015
A Ram Doo Sang-Kyi Lee

dotracheal tube and are composed of inspiratory and expiratory corrugated limbs. The two breathing tubes carry respiratory gases with volatile anesthetics to and from patients during general anesthesia. Although longer corrugated breathing tubes allow the anesthesia machine to be located farther from the patients, they are so long and flexible that they tend to hang down below the operating tab...

2018
Hozhabr Mozafari Shengmao Lin Linxia Gu Gary C.P. Tsui

To maximize the controllable energy absorption of corrugation troughs as observed in the single sided corrugated (SSC) tube, we proposed and tested a new structure design, i.e., double-sided corrugated (DSC) tube made of Al 6060-T6 aluminum alloy or CF1263 carbon/epoxy composite. Finite element models were developed to test the mechanical advantage of the DSC tube in comparison with both SSC an...

Journal: :Transactions of the Japan Society of Mechanical Engineers 1971

فرنیا, فرحناز, کریمی زارچی, محمدعلی,

Introduction : Hospital infections are one of the important reasons of mortality and incurred expenses. Therefore, we must control these infections by identifying contamination sources. The aim of this study was the determination of bacterial pollution of corrugated anesthesia sets in surgical rooms. Methods: This study was an analytic-description one performed in training hospitals of Yazd ci...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید