نتایج جستجو برای: connector
تعداد نتایج: 6072 فیلتر نتایج به سال:
Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...
BACKGROUND/AIM Increased airway resistance reduces the effectiveness of ventilation treatment. Endotracheal tubes (ETTs) and connectors contribute to resistance. However, the effect of a closed system suction (CSS) connector is not well known. We compared the in vivo resistance occurring with a CSS connector with that of the standard connector. MATERIALS AND METHODS This prospective study was...
OBJECTIVE The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. METHODS Finite element models rep...
High-level G3X(MP2)-RAD calculations have been carried out to examine the effect of interposing a "connector" group (W) on the interaction between a substituent (X) and the radical center in carbon-centered radicals ((•)CH(2)-W-X). The connector groups include -CH(2)-, -CH═CH-, -C≡C-, -p-C(6)H(4)-, -m-C(6)H(4)-, and -o-C(6)H(4)-, and the substituents include H, CF(3), CH(3), CH═O, NH(2), and CH...
The purpose of this study was to conduct static load-bearing tests on 4-unit Y-TZP all-ceramic fixed partial denture (FPD) frameworks with different cross-sectional areas and forms to evaluate the influence of connector design on fracture load. Each of the central, mesial and distal connectors was prepared with one of 2 different cross-sectional areas and one of 3 different forms (one circular ...
OBJECTIVE We evaluated the ability of a recently developed peritoneal dialysis (PD) connector to prevent the risk of bacterial transfer to the fluid path after simulated touch and airborne contamination. METHODS Staphylococcus epidermidis ATCC1228 and Pseudomonas aeruginosa ATCC27853 strains were used. For touch contamination, 2 μL of a standardized inoculum [1×10(8) colony-forming units (CFU...
Background: The choice of connector lies between plate, a bar or a combination of bars, which may cross the palate in various positions. Many opinions have been expressed concerning the acceptability to the patients of the various forms of palatal connectors but there have been few investigations. Objectives: The aim of this study is to compare subjective patients’ reactions to three maxillary ...
This study deals with the cumulative pitch variations in DIN male contacts. A connector provides a separable interface between two subsystems of an electronic system. DIN is a series of connector which stands for Deutsch Institut fur Normung. They are used for applications like switching, transmission, radio base stations, control units and machines. Connector manufacturing involves stamping, m...
BACKGROUND The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piece/ETT connector pairs with reduced instrumental dead space on CO2 elimination...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید