نتایج جستجو برای: conductometric detector
تعداد نتایج: 59181 فیلتر نتایج به سال:
A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, ...
This review presents the principles of conductometric measurements in ionic media and the equivalent electrical circuits of different designs for conductometric measurements. These types of measurements were first applied for monitoring biocatalytic reactions. The use of conductometric microtransducers is then presented and detailed in the case of pollutant detection for environmental monitorin...
The carbon dioxide flux at the air/water interface in lakes was calculated after the determination of H2CO3* (free CO2) and atmospheric CO2 using flow injection analysis (FIA) coupled to a conductometric detector. The method is based on the diffusion of CO2 through a hydrophobic membrane into a flow of deionized water, generating a gradient of conductivity proportional to the concentration of C...
We describe a procedure for the determination of hydrochloric acid concentration in gastric juice by means of a conductometric titration of the 50-fold diluted sample with an aqueous ammonia solution. The conductometric method of endpoint indication leads to a definite location of the equivalence point in the titration of hydrochloric acid. The proposed method is simple and accurate and shows a...
Very often, high-temperature operated gas sensors are cross-sensitive to oxygen and/or they cannot be operated in oxygen-deficient (rich) atmospheres. For instance, some metal oxides like Ga(2)O(3) or doped SrTiO(3) are excellent materials for conductometric hydrocarbon detection in the rough atmosphere of automotive exhausts, but have to be operated preferably at a constant oxygen concentratio...
Ti/PbO2/Sb2O3 electrode was used as indicator electrode in potentiometric and conductometric titration in aqueous solution at 298 K. The E-pH curve is linear with a slope of 0.0505 V/dec at 298 K which is close to the theoretical value 2.303RT/F (0.059 V at 298 K). The standard potential of this electrode, E, is computed with respect to the SCE as reference electrode. The recovery percentages f...
urease was immobilized on platinum electrode both by chemical binding and electropolymerization.the conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 m and linear dynamic range from 4.9×10-5 to 5.8×10-3 m for urea concentration when the enzyme is covalently immobilized on pt electrodes. conductometric transducers respond to the changes in ionic strength thereby le...
The reaction between NaAsO2 and oxalic acid was studied by pH-metric and conductometric measurements, applying the methods of continual variation and pH-metric and conductometric titration. It was found that oxalic acid forms a complex anion of the type [AsOC2O4]. The relative stability constant of the complex at ionic strengths, I, of 0.10 (log Kr = 4.70), 0.20 (log Kr = = 4.51), 0.50 (log Kr ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید