نتایج جستجو برای: column joint
تعداد نتایج: 261993 فیلتر نتایج به سال:
a parametrik investigation was conducted to study the non-linear behavior of precast and cast-in-place reinforced concrete beam-column connections subjected to tabas seismic forces (1979). the behavior of these types of connections in a four stories structure with respect to strength, ductility , stiffness, and bond deterioration at the joint core are presented and discussed. calculation result...
this article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. as the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. four different specimens have been analyzed. these models had some differences such as bolt arrangement and the presence or a...
─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...
conclusions we recognized this type of fracture and treated it similarly to both column fractures. we recommend that the classification of acetabular fractures be modified to include this type of fracture. introduction acetabular fractures are a common problem among young males. an acetabular fracture with disruption of the joint surface, if untreated, will rapidly lead to post-traumatic osteoa...
some considerable damage to steel structures during the hyogo-ken nanbu earthquake occurred. among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. the lessons from these phenomena led to the need for improved understanding of column base...
field’s awareness of the Life Safety Code®* (LSC). To address this need, The Joint Commission Perspectives® publishes the column Clarifications and Expectations, authored by George Mills, MBA, FASHE, CEM, CHFM, CHSP, director, Department of Engineering, The Joint Commission. This column clarifies standards expectations and provides strategies for challenging compliance issues, primarily in life...
Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید