Alireza Emami-Ardekani Alireza Mardanshahi, Faraz Kalantari, Mahmoud Bagheri Mohammad Sobhan Ardekani Nasim Namiranian Reza Nafisi-Moghadam Seid Kazem Razavi-Ratki, Seyed Hossein Razavi,

Introduction:In an ideal parallel-hole collimator, thickness of septal material should be sufficient to stop more than 95% of incident photons. However, some photons pass the septa without interaction or experience scattering before they reach the detector. In this study, we determined different contribution of collimator responses consist of geometrical response, septal penetr...

Journal: :Medical physics 2014
M Khan J Rehman J Chow

PURPOSE The purpose of this study is to investigate the dose-volume variations of planning target volume (PTV) and organs-at-risk (OARs) in prostate volumetric modulated arc therapy (VMAT) when using different collimator angles. It is because collimator angle awareness is essential for planner to produce an optimal prostate VMAT plan in a rational time. METHODS Single-arc VMAT plans at differ...

Journal: :Nuclear Engineering and Technology 2021

In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and air filter, was developed. A collimator applied to the system showed enhancement in resolution degradation efficiency. The efficiency were compared analyzed evaluate performance collimator. Thus, found be more important than as determining factor performance, from viewp...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1990
R E Malmin P C Stanley W R Guth

Angulation errors in collimator septa degrade tomographic resolution in SPECT due to mispositioning of events in the projection data. These errors should be small compared to other contributions to SPECT system resolution, such as intrinsic camera and collimator resolution, gantry alignment, and algorithmic smoothing. We describe a radioisotope technique to measure septal angulation errors over...

Journal: :Medical physics 2002
Gengsheng L Zeng Daniel Gagnon Christopher G Matthews Jeffery A Kolthammer Jason D Radachy William G Hawkins

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted plan...

Journal: :Journal of nuclear medicine technology 2011
Erin R Snay S Ted Treves Frederic H Fahey

UNLABELLED Our objective was to optimize the quality of (123)I-metaiodobenzylguanidine (MIBG) scans by using a medium-energy collimator to reduce high-energy-photon septal penetration. METHODS In addition to the 159-keV γ-ray, (123)I has a small abundance of energies above 400 keV that can compromise the image quality of MIBG studies because of septal penetration. Using a low-energy ultrahigh...

2012
Sudahar Harikrishnaperumal Gopalakrishna Kurup Murali Venkatraman Velmurugan Jagadeesan

Prolonged treatment execution time is a concern in CyberKnife robotic radiosurgery. Beam reduction and node reduction technique, and monitor unit optimization methods are adopted to reduce the treatment time. Usage of single collimator in the CyberKnife treatment plan can potentially reduce collimator exchange time. An optimal single collimator, which yields an acceptable dose distribution alon...

Journal: :Medical physics 2012
J Fan Q Xu L Wang L Jin J Li T Lin S Hayes T Tam C Ma

PURPOSE There are two collimation systems associated with the CyberKnife system, the fixed cone collimator and the Iris collimator. The Iris collimator is used more frequently because of its superior flexibility. However, sometimes treatments have to be canceled or postponed due to Iris collimator mechanical failures. The purpose of this study is to investigate the feasibility of switching coll...

2018
Ming‐Hsien Li Sheng‐Fang Huang Chih‐Chieh Chang Jang‐Chun Lin Jo‐Ting Tsai

PURPOSE Hypofractionated radiotherapy can reduce treatment durations and produce effects identical to those of conventionally fractionated radiotherapy for treating prostate cancer. Volumetric arc radiotherapy (VMAT) can decrease the treatment machine monitor units (MUs). Previous studies have shown that VMAT with multileaf collimator (MLC) rotation exhibits better target dose distribution. Thu...

Journal: :Medical physics 2007
Edward E Graves Hu Zhou Raja Chatterjee Paul J Keall Sanjiv Sam Gambhir Christopher H Contag Arthur L Boyer

Treatment of small animals with radiation has in general been limited to planar fields shaped with lead blocks, complicating spatial localization of dose and treatment of deep-seated targets. In order to advance laboratory radiotherapy toward what is accomplished in the clinic, we have constructed a variable aperture collimator for use in shaping the beam of microCT scanner. This unit can image...