نتایج جستجو برای: cine

تعداد نتایج: 6582  

Ahmad Keshtkar, Asghar Mesbahi, Naser Aslanabadi Parinaz Mehnati

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

2015
Lamya A Atweh Karen Lyons Ramkumar Krishnamurthy Amol Pednekar Rajesh Krishnamurthy

Background This is a pilot study to evaluate the performance of whole-heart isotropic RT-3D cine SSFP sequence as an efficient single solution for assessment of morphology and function in CHD by comparing it to: 1. Short axis (SA) 2D cine SSFP for LV volumetry and function 2. Multiplanar 2D cine SSFP for intracardiac morphology 3. Cine 2D SSFP and gadolinium (Gd)-enhanced 3D MRA for aortic root...

2016
Tomoyuki Kido Teruhito Kido Masashi Nakamura Kouki Watanabe Michaela Schmidt Christoph Forman Teruhito Mochizuki

BACKGROUND Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard ci...

2018
Robert R. Edelman Ali Serhal Amit Pursnani Jianing Pang Ioannis Koktzoglou

BACKGROUND Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The te...

Journal: :Magnetic resonance in medicine 2013
Li Feng Monvadi B Srichai Ruth P Lim Alexis Harrison Wilson King Ganesh Adluru Edward V R Dibella Daniel K Sodickson Ricardo Otazo Daniel Kim

For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm...

2011
Carlos Eduardo Rochitte Clerio F Azevedo Miguel A Rosário Maria H.R Siqueira Victor Monsão Manoj Saranathan Thomas K Foo Roberto Kalil Filho Giovanni G Cerri José A. F Ramires

INTRODUCTION The accurate and reproducible assessment of cardiac volumes, function, and mass is of paramount importance in cardiology. In the present study we sought to determine whether the 3D cine-magnetic resonance (MR) technique, using the variable asymmetric sampling in time (VAST) approach, provided an accurate assessment of LV functional parameters when compared with the conventional 2D ...

2017
So Hyeon Bak Sung Mok Kim Sung-Ji Park Min-Ji Kim Yeon Hyeon Choe

Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breathhold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were r...

2015
Gabriel C Camargo Leticia R Sabioni Fernanda Erthal Ralph Strecker Michaela Schmidt Michael O Zenge Ilan Gottlieb

Background Segmented cine imaging with a steady-state free precession sequence (CINE-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass. It requires multiple breath-holds to cover the entire ventricles, thus being prone to misalignment of consecutive slices, time consuming and dependent on breath-hold (BH) capability. Real-time cine avoids those limitation...

2016
Masashi Nakamura Tomoyuki Kido Yoshiaki Komori Michaela Schmidt Christoph Forman Kouki Watanabe Teruhito Mochizuki

Background Electrocardiogram (ECG)-gated breath-hold cardiac cine magnetic resonance imaging (MRI) is generally accepted as the gold standard for left-ventricular (LV) volume assessment. However, it may fail in patients with arrhythmia, impaired breath-hold capacity, and poor ECG gating. Recently, sparse real-time (RT) cine using a prototype sequence with sparse sampling and iterative reconstru...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2008
K Lance Gould Tinsu Pan Catalin Loghin Nils P Johnson Stefano Sdringola

UNLABELLED Cardiac PET/CT is optimized by cine CT with dedicated shift software for manual correction of attenuation-emission misregistration. Separate rest and stress CT scans incur greater radiation dose to patients than does standard helical PET/CT or "pure" PET using rotating rod attenuation sources. To reduce radiation dose, we tested quantitative accuracy of using a single poststress cine...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید