نتایج جستجو برای: cathode ray tube

تعداد نتایج: 403933  

Journal: :The Journal of the Institute of Television Engineers of Japan 1968

2015
Kevin Cheng Yi-Ping Chou Ming-Der Ger Kung-Hsu Hou

A self-focusing field emission (FE) X-ray tube with a large-area cathode design was simulated and fabricated. The designed X-ray tube had a cylindrically symmetric geometry; the diameter of the cathode and the anode was 15 mm, and the cathode-anode distance was 20 mm. Owing to the unique cup-shaped design of the cathode, the electron beam emitted from the large-area cathode was focused onto the...

ذبیح‌زاده, منصور, شمس, نسیم, غلامی, مهرداد, کرمی, وحید,

Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male pa...

Journal: :The Journal of the Institute of Television Engineers of Japan 1969

Journal: :pollution 2015
raymond njinga sameul mamman

exposure to radiation from different types of television sets was measured to ascertain the levels of hazards posed to the human biological system. measurement of the annual radiation dose hazards was performed using a halogen-quenched gm tube with thin mica end window having a density of 1.5 mg/cm2, effective window diameter of 0.360 inch and side wall of 0.012 inch thick. the gm tube was plac...

Journal: :Journal of the Society of Materials Science, Japan 2000

1999
Peyma Oskoui Elizabeth Pirrotta

CRT white point, adapted white point, chromatic adaptation, viewing condition, monitor characterization, psychophysics, neutral point, mixed mode illumination, incomplete adaptation An iterative psychophysical algorithm is designed and implemented to determine the adapted white point for cathode ray tubes (CRTs) in a given viewing condition. This algorithm can accurately determine the chromatic...

Journal: Pollution 2015

Exposure to radiation from different types of television sets was measured to ascertain the levels of hazards posed to the human biological system. Measurement of the annual radiation dose hazards was performed using a halogen-quenched GM tube with thin mica end window having a density of 1.5 mg/cm2, effective window diameter of 0.360 inch and side wall of 0.012 inch thick. The GM tube was plac...

Exposure to radiation from different types of television sets was measured to ascertain the levels of hazards posed to the human biological system. Measurement of the annual radiation dose hazards was performed using a halogen-quenched GM tube with thin mica end window having a density of 1.5 mg/cm2, effective window diameter of 0.360 inch and side wall of 0.012 inch thick. The GM tube was plac...

Journal: :The Journal of the Institute of Television Engineers of Japan 1962

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید