نتایج جستجو برای: bone wires

تعداد نتایج: 317060  

Journal: :archives of trauma research 0
eric m. padegimas department of orthopedic surgery, thomas jefferson university hospital, philadelphia, usa; department of orthopedic surgery, thomas jefferson university hospital, 1025 walnut street, room 516 college, philadelphia, usa. tel: +1-2159551500; +1-8606040902, fax: +1-2155030530 william j. warrender department of orthopedic surgery, thomas jefferson university hospital, philadelphia, usa christopher m. jones department of orthopedic surgery, the rothman institute, thomas jefferson university hospital, philadelphia, usa asif m. ilyas department of orthopedic surgery, the rothman institute, thomas jefferson university hospital, philadelphia, usa

conclusions metacarpal neck fractures are a common injury in young and active patients that results in substantial missed time from work. while the surgical indications are well-described, there is no consensus on the optimal treatment modality because of high complication rates. dorsal plating has higher complication rates than closed reduction and percutaneous pinning, but is necessary in com...

2005
Eric Rachlin John E. Savage

The nanowire crossbar is a promising nanotechnology for assembling memories and circuits. In both, a small number of lithographically produced mesoscale wires (MWs) must control a large number of nanoscale wires (NWs). Previous strategies for achieving this have been vunerable to misalignment. In this paper, we introduce core-shell NWs, which eliminate misalignment errors. We also give a two-st...

Journal: :dental research journal 0
mehdi mehdikhani-nahrkhalaji mohammad hossein fathi vajihesadat mortazavi sayed behrouz mousavi ali akhavan abbas haghighat

poly (lactide-co-glycolide)/bioactive glass/hydroxyapatite (pbgha) and poly (lactide-co-glycolide)/ bioactive glass (pbg) nanocomposite coatings with bone. materials and methods: sol-gel derived 58s bioactive glass nanoparticles, 50/50 wt% poly (lactic acid)/poly (glycolic acid) and hydroxyapatite nanoparticles were used to prepare the coatings. the nanocomposite coatings were characterized by ...

جمشیدی, نیما, عفت‌پرور, محمدرضا, کریمیان, علی‌رضا,

Background: Cooling is one of the main processes in bone temperature decrement, while drilling. this experiment was conducted for examination of alcohol effect as cooler in prevention of thermal necrosis. Methods: Bovine femur bone was considered as specimen and inclusions criteria for this study were: femur bone, cortical area and without bone periosteum. Drilling process w...

2017
Arnold V. Popkov Elena N. Gorbach Natalia A. Kononovich Dmitry A. Popkov Sergey I. Tverdokhlebov Evgeniy V. Shesterikov

A lot of research was conducted on the use of various biomaterials in orthopedic surgery. Our study investigated the effects of nanostructured calcium-phosphate coating on metallic implants introduced into the bone marrow canal. Stainless steel or titanium 2-mm wires (groups 1 and 2, respectively), and hydroxyapatite-coated stainless steel or titanium wires of the same diameter (groups 3 and 4,...

Journal: :iranian journal of veterinary science and technology 0
sadık yayla engin kilic vedat baran celal sahin ermutlu ugur aydin

the aim of this study was to evaluate the long-term outcome of treatment using kirschner wires and tensioning bands for tarsocrural luxation with malleolus fractures resulting from trauma in dogs. eight dogs with tarsocrural luxation due to malleolus fracture were selected. following intrathecal anesthesia, the malleolus bone was returned to its normal position using two kirschner wires and ten...

2011
Karan Gulati Moom Sinn Aw Dusan Losic

Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems. This study presents the use of titanium [Ti] wires with titania nanotube [...

2014
Sang Hyuk Lee Jun Young Choi Dong Hee Kim Bun Jung Kang Dae Cheol Nam Hong Kwon Yoon Sun Chul Hwang

PURPOSE The object of this study was to determine the shortest possible distances of antero-medial (AM) and postero-lateral (PL) guide wire tunnel positions required to prevent femoral bone tunnel communication in double-bundle anterior cruciate ligament (ACL) reconstruction using human cadaver knees. MATERIALS AND METHODS The centers of femoral AM and PL bundles of 16 cadaveric knees were dr...

Journal: :Acta of bioengineering and biomechanics 2008
Michał Wychowański Marcin Obrebski Kazimierz Rapała Andrzej Wit Jan Gajewski Krzysztof Marczak

In this study, the authors assess the strength of proximal humerus fracture fixation using different methods. The strength, while pulling out the chosen single Kirschner wires implanted in porcine bone, has been examined. Tests concerning the strength of fixation with different types of implants have been carried out on prepared models. We observed the maximum strength of the bone-single wire c...

Alireza Khoshsirat Elahe Tohidi Maryam Hashemipour, Sahand Samieirad, Vajiheh Mianbandi,

Abstract The prevalence of mandibular fracture is relatively lower in the pediatric population compared to adults. The treatment of these fractures is more challenging for oral and maxillofacial surgeons due to the concerns regarding mandible growth and the presence of developing tooth buds. According to the literature, conventional methods (e.g., soft diets or closed red...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید