نتایج جستجو برای: bearing wall system
تعداد نتایج: 2436281 فیلتر نتایج به سال:
Structural walls commonly used as efficient structural elements to resist lateral and vertical loads. Diverse performance of bearing wall system in past earthquakes, motivates investigation on the adequacy of current seismic design provision for these walls. This study considers seismic performance of model walls of bearing wall and building frame systems designed as ordinary and special struct...
This paper describes the testing of Profiled Steel Sheet Dry Board (PSSDB) load bearing wall system. Experimental tests were conducted on various PSSDB wall samples, with and without infill materials to study its effect on the PSSDB load bearing wall performance. A proprietary profiled steel sheet, Ajiya Cliplock (0.48 mm thick) attached to Cemboard (10 mm thick) on one side, and Cemplank (10 m...
The present study compared the performance of soldier pile and concrete bearing pad anchored wall facings. Using Abaqus finite element software, two case studies have been precisely represented for the facing designs and effects of the parameters of soil type, spacing of anchors and facings, surcharge and facing sizes were investigated. The analysis results indicate that the soldier pile method...
the purpose of this research was to assess the influence of several orchard systems involving trees trained to different leader numbers on growth, cropping, and fruit quality of two apple cultivars. the study was conducted during 1994-2007 at the fruit experimental station in samotwór, next to wrocław (south-western poland). one-year-old trees of ‘elstar’ and ‘jonagold’ cultivars on the m.9 roo...
In this paper evaluation of seismic capacity of a historical building is carried out. It had been used as a national library about 40 years ago. Also, before that, it had been constructed as a part of a Royal complex. This building has been constructed by traditional methods using bricks and mortars. The ceilings system of the structure consists of jack arches. Also, the roof of the building ha...
Despite overall improved outcomes with open reduction and internal fixation of acetabular fractures, posterior wall fractures show disproportionately poor results. The effect of weight bearing on outcomes of fracture management has been investigated in many lower extremity fractures, but evidence-based recommendations in posterior wall acetabular fractures are lacking. The authors systematicall...
A staggered pre-cast RC wall system is proposed. The can provide the flexibility of interior spaces and simplifications constructions. To investigate structural properties system, experiments using scaled specimens were carried out with varying vertical load acting on wall. experimental results showed that capacity could be evaluated by sum friction force connection area dowel reinforcement bar...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید