نتایج جستجو برای: beamnrc simulation

تعداد نتایج: 559052  

Journal: :journal of paramedical sciences 0
danial seifi makrani department of medical physics, faculty of medical sciences, semnan university of medical sciences, semnan, iran hadi hasanzadeh cancer research center, department of medical physics, semnan university of medical sciences, semnan, iran tayyeb allahverdi pourfallah department of biochemistry and biophysics, faculty of medicine, mazandaran university of medical sciences, sari, iran arash ghasemi department of radiology and radiation oncology, faculty of medicine, mazandaran university of medical sciences, sari, iran majid jadidi department of medical physics, faculty of medical sciences, semnan university of medical sciences, semnan, iran hamed babapour guilan oncology center (goc), rasht, iran

the monte carlo method can be used to describe any technique that approximates solutions to quantitative problems through statistical sampling. this method is considered to be the most accurate method for dose calculation in radiotherapy. for complete modeling of a linear accelerator, it is required that the manufactured information covers all data, but some data such as primary electron energy...

Journal: :World Journal of Engineering and Technology 2022

Purpose: To model the ELEKTA COMPACT accelerator head by using EGSnrc/BEAMnrc/DOSXYZnrc and to validatethe simulation according depth-dose lateral profiles of different radiation fields measured water phantom. Methods: IBA Blue Water Phantom2 CC13 Ionization Chamber were used measure curves at 10 cm × field profile depth underwater. In BEAMnrc, main components initial electron beam are establis...

2017
Mikaeil Molazadeh Ahad Zeinali Mostafa Robatjazi Alireza Shirazi Ghazale Geraily

This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Radiation transmission and abutting leaf leakage relevant to the LinaTech DMLC H...

Journal: :Medical physics 2012
C Borges M Zarza-Moreno E Heath N Teixeira P Vaz

PURPOSE The most recent Varian(®) micro multileaf collimator (MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRC Monte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. METHODS The Varian(®) Trilogy(®) (2300C/D) accelerator m...

Journal: :iranian journal of radiation research 0
gh.r. fallah mohammadi1 department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira n. riyahi alam department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira gh. geraily department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira r. paydar radiation sciences department, faculty of allied medicine, iran university of medical sciences, tehran, iran

background:  this study presents patient specific and organ dose estimation in computed tomography (ct) imaging of thorax directly from patient ct image using monte carlo simulation.  patient's ct image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. materials and methods: egsnrc /beamnrc monte c...

Ali Shabestani Monfared, Mohammad Davoudi Mohammad Rahgoshay

Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...

Gholam Reza Ataei Hamed babapour Mohammad Davoudi

Introduction: Previous studies have shown that a Monte Carlo method for the transportations photon beam in medical linear accelerator is a good way. Strip of simulation can be used to measure the dose distribution in phantoms and patients' body. EGSnrc Code is the only code written for use in the field of radiation therapy that has many subset codes that BEAMnrc code is an impo...

ژورنال: سنجش و ایمنی پرتو 2018

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید