نتایج جستجو برای: beam gantry

تعداد نتایج: 114050  

Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...

2015
Iori Sumida Hajime Yamaguchi Hisao Kizaki Keiko Aboshi Mari Tsujii Yuji Yamada Masashi Yagi Kazuhiko Ogawa

Pretreatment dose verification with beam-by-beam analysis for intensity-modulated radiation therapy (IMRT) is commonly performed with a gantry angle of 0° using a 2D diode detector array. Any changes in multileaf collimator (MLC) position between the actual treatment gantry angle and 0° may result in deviations from the planned dose. We evaluated the effects of MLC positioning errors between th...

2017
T. Sedaghatian M. Momennezhad S.H. Rasta Y. Makhdoomi S. Abdollahian

PURPOSE Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch. MATERIALS AND METHODS In this study, we...

2007
George Ciangaru James N. Yang Patrick J. Oliver Martin Bues Mengping Zhu Fumio Nakagawa Hitoshi Chiba Shin Nakamura Hirofumi Yoshino Mosumi Umezawa Alfred R. Smith

We present a technique--based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery--for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collimated by a circular aperture at its central axis and is then intercepted by a small steel sphere...

2008
Rudolf Dölling Shixiong Lin Boris Keil Paul Scherrer

The dedicated new medical facility PROSCAN has restarted the treatment of deep seated tumours with proton beams at Gantry 1. The beam lines to the new gantry 2 for the further development of the spot-scanning technology, as well as to the replacement of the long established OPTIS facility for the treatment of eye melanoma, and to a material irradiation area, are in the commissioning phase. An o...

2016
Ilana Feain Chun-Chien Shieh Paul White Ricky O'Brien Sandra Fisher William Counter Peter Lazarakis David Stewart Simon Downes Michael Jackson Siddhartha Baxi Brendan Whelan Kuldeep Makhija Chen-Yu Huang Michael Barton Paul Keall

PURPOSE The purpose of this article is to present the first imaging experiments to demonstrate the functional equivalence between a conventional rotational gantry and a fixed-beam imaging geometry, and the feasibility of an iterative image-reconstruction technique under gravitational deformation. METHODS AND MATERIALS Experiments were performed using an Elekta Axesse with Agility MLC and XVI,...

2014
Yoshiyuki Iwata K. Noda T. Murakami T. Shirai T. Furukawa T. Fujita S. Mori S. Sato K. Mizushima K. Shouda T. Fujimoto H. Arai T. Ogitsu T. Obana N. Amemiya T. Orikasa S. Takami S. Takayama

An isocentric superconducting rotating-gantry for heavy-ion therapy is being developed [1]. This rotating gantry can transport heavy ions having 430 MeV/u to an isocenter with irradiation angles of over ±180°, and is further capable of performing fast raster-scanning irradiation [2]. A layout of the beam-transport line for the compact rotating-gantry is presented in Fig. 1. The rotating gantry ...

2017
Ulrich W. Langner John G. Eley Lei Dong Katja Langen

PURPOSE Commissioning beam data for proton spot scanning beams are compared for the first two Varian ProBeam sites in the United States, at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (SPTC). In addition, the extent to which beams can be matched between gantry rooms at MPTC is investigated. METHOD Beam data for the two sites were acquired with independent dos...

2011
Evan R. Sengbusch Thomas R. Mackie

The purpose of this study was to determine the maximum proton kinetic energy required to treat a given percentage of patients eligible for stereotactic radiosurgery (SRS) with coplanar arc-based proton therapy, contingent upon the number and location of gantry angles used. Treatment plans from 100 consecutive patients treated with SRS at the University of Wisconsin Carbone Cancer Center between...

2014
Jamil Lambert Christian Bäumer Benjamin Koska Xiaoning Ding

We present here a novel method for using a single device in the daily quality assur- ance (QA) of pencil beam scanning (PBS) proton beams and an improved method for uniform scanning (US). The device can be used to measure the spot position, spot sigma, range, output, collinearity of the X-ray system and proton beam, and to QA the first scatterers and a number of other imaging and mechanical che...