نتایج جستجو برای: balloon dilator

تعداد نتایج: 29002  

Journal: :international journal of pediatrics 0
imad absah assistant professor of pediatrics and adolescents, division of pediatric gastroenterology mayo clinic college, medicine rochester, mn, usa. manoochehr karjoo professor of pediatrics and adolescents, division of pediatric gastroenterology suny upstate, medical university syracuse, ny, usa. mirza b beg assistant professor of pediatrics and adolescents, division of pediatric gastroenterology, suny upstate, medical university syracuse, ny, usa.

congenital esophageal atresia needs to be surgically corrected as soon as possible. some will present with post surgical stricture that needs to be dilated by a balloon dilator. this procedure is difficult in premature born due to infant esophageal size and availability of equipments. we herby report the first case in a premature infant with post surgical esophageal stricture of esophageal atre...

Imad Absah Manoochehr Karjoo, Mirza B Beg

Congenital esophageal atresia needs to be surgically corrected as soon as possible. Some will present with post surgical stricture that needs to be dilated by a balloon dilator. This procedure is difficult in premature born due to infant esophageal size and availability of equipments. We herby report the first case in a premature infant with post surgical esophageal stricture of esophageal atre...

2017
Ryosuke Shindo Shigeru Aoki Naohiro Yonemoto Yuriko Yamamoto Junko Kasai Michi Kasai Etsuko Miyagi

OBJECTIVE To compare the efficacy and safety of hygroscopic dilators and balloon catheters for ripening of the cervix in induction of labor. STUDY DESIGN This retrospective, observational study used data from the Successive Pregnancy Birth Registry System of the Japan Society of Obstetrics and Gynecology from 2012 to 2014. Nulliparous women in whom labor was induced by mechanical methods of c...

Journal: :Journal of clinical and diagnostic research : JCDR 1973
R Francis

A well executed transseptal puncture is crucial for successful percutaneous transvenous mitral balloon valvotomy. We report a case of accidentally damaged Mullins sheath dilator. Due to immediate unavailability of another dilator at cardiac catheterization laboratory, angioplasty guidewire and balloon was used as an additional assisting armamentarium for successful percutaneous transvenous mitr...

Journal: :The Journal of bone and joint surgery. British volume 2010
G W Shen N Q Wu N Zhang Z S Jin J Xu G Y Yin

This study prospectively compared the efficacy of kyphoplasty using a Jack vertebral dilator and balloon kyphoplasty to treat osteoporotic compression fractures between T10 and L5. Between 2004 and 2009, two groups of 55 patients each underwent vertebral dilator kyphoplasty and balloon kyphoplasty, respectively. Pain, function, the Cobb angle, and the anterior and middle height of the vertebral...

Journal: :Turkish journal of urology 2013
Burak Özçift Kaan Bal Çetin Dinçel

OBJECTIVE In this study, we compared our experience using balloon and amplatz dilatation in percutaneous nephrolithotomy (PCNL). We also evaluated peri- and postoperative variables, including success rates. MATERIAL AND METHODS Two hundred renal stone patients (123 men/77 women) underwent PCNL at the Urology Clinic of İzmir Atatürk Training and Research Hospital from September 2005 to May 201...

Journal: :Surgical endoscopy 1999
T Tomonaga S G Houghton C J Filipi R A Hinder J Hunter B Dallemagne N Katkhouda R Kozarek T R DeMeester R Deeik Y Shiino Z T Awad R E Marsh

BACKGROUND Intraluminal gastric surgery provides a new treatment option for various disease processes. This study assesses the safety of a new large-diameter percutaneous endoscopic gastrostomy (PEG) for intraluminal surgery. METHODS Investigators at six institutions were asked to complete a standard questionnaire to assess the difficulties associated with the assembly and introduction of the...

Journal: :Gut 1986
J Cox G K Buckton J R Bennett

A newly available balloon dilator for the treatment of achalasia and its advantages over existing instruments are discussed. Our experience with its use in seven patients is described.

Journal: :The Medical journal of Malaysia 1995
P H Ding

This study evaluated the efficacy and safety of endoscopic pneumatic balloon dilatation as the initial treatment for achalasia of the cardia. 15 patients with achalasia underwent a total of 19 dilatations using the new polyethylene dilator (Microvasive Rigiflex Balloon Dilator) over the last 6 years. An overall treatment success rate of 93% was achieved. 11 patients (73.3%) have not required a ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید