نتایج جستجو برای: automated perimetry
تعداد نتایج: 130533 فیلتر نتایج به سال:
modern computerized technology enables more complex visual stimuli and test procedures to be in-corporated into conventional perimetry resulting in several developments in automated perimetry that have contributed to more efficient diagnosis and management of eye diseases. this review will cover a number of advances in automated perimetry including frequency doubling technology perimetry, short...
purpose : to evaluate the efficacy of pattern visual evoked potentials (pvep), standard automated perimetry (sap), short-wavelength automated perimetry (swap), contrast sensitivity (cs), stereoacuity testing in detecting subclinical visual impairment in visually asymptomatic patients with multiple sclerosis (ms) and no history of optic neuritis methods : twenty-seven eyes of 27 patients (7 male...
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
purpose : to evaluate the effects of memantine on improving visual function in patients with acute nonarteritic anterior ischemic optic neuropathy (naion) methods : this was a prospective, double masked, randomized, clinical trial. the study involved 47 subjects with unilateral naion of less than 8 weeks duration. eligible patients were randomly allocated to take either memantine tablets (5 mg ...
PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید