نتایج جستجو برای: artisan iol

تعداد نتایج: 2687  

Journal: :Journal of cataract and refractive surgery 2007
Nayyirih G Tahzib Fred A G J Eggink Monica T P Odenthal Rudy M M A Nuijts

We report 2 patients who had radial keratotomy (RK) to correct myopia. The first patient developed a postoperative hyperopic shift and cataract. Nine years post RK, she had intracapsular cataract extraction and implantation of an Artisan aphakic intraocular lens (IOL). Twenty years post RK, hyperopia and astigmatism progressed to +7.0 -5.75 x 100 with a best corrected visual acuity (BCVA) of 20...

Journal: :Journal of refractive surgery 2004
Mihai Pop Yves Payette

PURPOSE To study a paired-match comparison between refractive lens exchange with pseudophakic IOL implant (RLE) and Artisan phakic IOL for high hyperopia. METHODS Nineteen eyes (12 patients, 20 to 41 years old) with an Artisan phakic IOL (Model 203: 1.00-D increment) for hyperopia from +2.75 to +9.25 D were matched to 19 eyes (15 patients, 26 to 46 yr) with hyperopia from +2.75 to +7.50 D, wh...

Journal: :Journal of cataract and refractive surgery 2004
Ivanka J van der Meulen Frans P Gunning Muriel G Vermeulen Marc D de Smet

PURPOSE To report the results of pars plana vitrectomy (PPV) for retained lens fragments with implantation of an Artisan intraocular lens (IOL) (Ophtec) to correct aphakia. SETTING University-based referral center. METHODS In this retrospective case-controlled study, patients who had had a PPV to remove dislocated lens fragments and implantation of an Artisan IOL for pseudophakic correction...

2014
Ahmad Kheirkhah Mojgan Nikdel Hadi Ghadimi

Implantation of iris-claw Artisan intraocular lens (IOL) is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs' heterochromic iridocyclitis (FHI) due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphak...

Journal: :Journal of cataract and refractive surgery 2004
José L Menezo Cristina Peris-Martínez Angel L Cisneros Rafael Martínez-Costa

PURPOSE To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. SETTING La Fe University Hospital, Department of Ophthalmology, and the Fundación Oftalmológica del Mediterráneo, Valencia, Spain. METHODS In this prospective comparative study, a phakic IOL was implanted in 217 highly myopi...

2010
Farid Karimian Mohammad-Mehdi Sadoughi

Endothelial keratoplasty (EK) is the most exciting recent development in corneal transplantation. It has experienced surprisingly rapid growth in a very short period of time. One of the indications for EK is pseudophakic bullous keratopathy. However, concomitant intraocular lens (IOL) exchange, if indicated, may prove challenging. Some surgeons routinely perform IOL exchange with a scleral-fixa...

Journal: :Journal of cataract and refractive surgery 2002
Mihai Pop Yves Payette Magdi Mansour

PURPOSE To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM). METHODS Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber dept...

Journal: :Journal of cataract and refractive surgery 2006
Günhal Kamburoğlu Mehmet Bahadir Aylin Ertan

We report a 50-year-old patient who had secondary implantation of an aphakic Artisan (Ophtec) intraocular lens (IOL) that was placed vertically in the anterior chamber. The patient had had a perforating injury to the cornea that required corneal wound repair, lensectomy, and anterior vitrectomy. Because of the localized traumatic aniridia, the Artisan IOL could not be placed horizontally. Three...

Journal: :Investigative ophthalmology & visual science 2012
Nienke Visser Tos T J M Berendschot Noël J C Bauer Rudy M M A Nuijts

PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eye...

Journal: :بینا 0
پرویز ملکی فرد p malekifar ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران حسین محمد ربیع h mohammad rabie ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranمرکز تحقیقات مهندسی بافت چشم- - تهران- ایران فاطمه جوادی f javadi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranمرکز تحقیقات مهندسی بافت چشم- دانشگاه علوم پزشکی شهید بهشتی- تهران- ایران حامد اسفندیاری h esfandiari ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران

purpose: to evaluate the efficacy and safety of primary aphakic artisan–verysise intraocular lens (iol) implantation during complicated cataract surgery. methods: the study is a retrospective analysis of 49 eyes that underwent primary aphakic artisan iol implantation for complicated cataract surgery. compiled data included demographic information, visual outcomes and complications. pre- and pos...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید