نتایج جستجو برای: artiflex

تعداد نتایج: 32  

2017
Alireza Hedayatfar Hassan Hashemi Soheila Asghari Negin Badie Mohammad Miraftab

Purpose To compare chronic subclinical inflammation induced after implantation of Artisan vs. Artiflex phakic intraocular lenses (pIOLs). Methods This prospective, comparative, non-randomized study included consecutive patients with moderate to high myopia who underwent Artisan or Artiflex pIOL implantation with standard surgery and postoperative care. Anterior chamber flare was assessed quan...

2014
Farid Karimian Alireza Baradaran-Rafii Seyed Javad Hashemian Ali Hashemloo Mohammad Ebrahim Jafari Mehdi Yaseri Elham Ghahari Shadi Akbarian

PURPOSE To compare the visual outcomes and complications of three different types of phakic intraocular lenses (PIOLs), for correction of moderate to high myopia. METHODS We reviewed 112 myopic eyes undergoing PIOL implantation using Artisan (40 eyes), Artiflex (36 eyes), and implantable collamer lens (ICL, 36 eyes). Best corrected visual acuity (BCVA), intraocular pressure (IOP), pachymetry,...

2013
Joo Youn Shin Jae Bum Lee Kyoung Yul Seo Eung Kweon Kim Tae-im Kim

PURPOSE To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometr...

Journal: :Journal of cataract and refractive surgery 2008
Nayyirih G Tahzib Scott M MacRae Geunyoung Yoon Tos T J M Berendschot Fred A G J Eggink Fred Hendrikse Rudy M M A Nuijts

PURPOSE To evaluate higher-order aberrations (HOAs) after implantation of Artiflex phakic intraocular lenses (pIOLs). SETTING Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands. METHODS This retrospective comparative case series comprised 27 eyes (14 patients) that had Artiflex pIOL implantation and 22 eyes (13 patients) that had Artisan pIOL implantation...

Journal: :Journal of cataract and refractive surgery 2008
Thomas Kohnen Magda Cichocki Michael J Koss

PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Op...

2014
Tiago Bravo Ferreira Joana Portelinha

PURPOSE To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was...

Journal: :American journal of ophthalmology 2006
Julien Coullet José-Luis Guëll Pierre Fournié Hélène Grandjean Javier Gaytan Jean-Louis Arné François Malecaze

PURPOSE To compare refractive performance of Artisan (Ophtec, Groningen, The Netherlands) or Verisyse phakic intraocular lens and its foldable version, Artiflex (Ophtec), for the correction of moderately high myopia. DESIGN Randomized pilot study. METHODS setting: Institutional practice. patient population: Thirty-one patients with myopia that ranged from -6 to -14 diopters (D). interventio...

Journal: :Acta medica Iranica 2013
Hassan Hashemi Mansour Taherzadeh Mehdi Khabazkhoob

To assess the one year results of Artiflex Phakic intraocular lens (IOL) implantation in the treatment of high myopia. In this non-random interventional study, myopic patients with spherical equivalent worse than -5.0 diopters (D) who were not eligible for laser surgery were assessed. All patients had refraction, uncorrected and best corrected visual acuity tests (UCVA and BCVA), endothelial ce...

2011
Gonzalo Muñoz

We describe the use of power vector analysis in quantifying the amount of lens rotation and assesing the subsequent correction in a case of rotated Artiflex toric phakic intraocular lens (pIOL) (Ophtec BV, Netherlands). A 33 year old patient was corrected by bilateral implantation of Artiflex toric pIOLs for high myopia and astigmatism. Two months after the surgery the patient reported worse vi...

Journal: :بینا 0
فرید کریمیان f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی علیرضا برادران رفیعی a baradaran rafii ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی جواد هاشمیان j hashemian tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران علی هاشملو a hashemloo ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی ابراهیم جعفری e jafari tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران مهدی یاسری m yaseri ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranگروه بهداشت و آمار حیاتی- دانشگاه علوم پزشکی تهران

purpose: to compare visual outcomes and surgical complications of three phakic intraocular lenses (piols); artisan, artiflex and the implantable collamer lens (icl) for correction of moderate to high myopia. methods: in this historical cohort study, 112 myopic eyes that were operated between 2005 and 2010 and implanted with one of these three piols were evaluated (artisan 40 eyes, artiflex 36 e...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید