نتایج جستجو برای: al electrode

تعداد نتایج: 504470  

Journal: :analytical and bioanalytical chemistry research 2014
a. shokrollahi a. abbaspourb a. naghashian haghighia a. h. kianfar

a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m  with nernstian slope of 19.64 ± 0.15 mv decade-1...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

In this research, we reported a novel modified carbon ceramic electrode (CCE) using Ni/Al Layered double hydroxide as modifier was fabricated by sol-gel technique. The Ni/Al Layered double hydroxide modified sol gel derived carbon ceramic (Ni/Al LDH-SGD-CC) electrode was used for electrocatalytic oxidation of acetaldehyde. The oxidation of acetaldehyde happens at the potential where Ni (III) sp...

Journal: :international journal of environmental research 2011
e. sekman s. top e. uslu g. varank m.s. bilgili

the present study investigated oil/water demulsification and treatment of oily wastewater originated from port waste reception facilities by electro coagulation using aluminum electrodes in a batch reactor. the efficiency of al electrodes in removing ss, cod, and oil & grease from wastewater with different current densities and operational times were investigated. the characteristics of th...

Journal: :international journal of environmental research 0
e. sekman yildiz technical university, environmental engineering department, 34220 esenler, istanbul, turkey s. top yildiz technical university, environmental engineering department, 34220 esenler, istanbul, turkey e. uslu yildiz technical university, environmental engineering department, 34220 esenler, istanbul, turkey g. varank yildiz technical university, environmental engineering department, 34220 esenler, istanbul, turkey m.s. bilgili yildiz technical university, environmental engineering department, 34220 esenler, istanbul, turkey

the present study investigated oil/water demulsification and treatment of oily wastewater originated from port waste reception facilities by electro coagulation using aluminum electrodes in a batch reactor. the efficiency of al electrodes in removing ss, cod, and oil & grease from wastewater with different current densities and operational times were investigated. the characteristics of the was...

A. Abbaspourb A. H. Kianfar A. Naghashian Haghighia A. Shokrollahi,

A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M  with Nernstian slope of 19...

Journal: :international journal of environmental research 2011
m. behbahani m.r. alavi moghaddam m. arami

this study presents a comparison between aluminum and iron plate electrodes on phosphate removal from aqueous solutions by electrocoagulation process. the effectiveness of main operational parameters such as initial ph, initial phosphate concentration and current density were examined. in addition, treated solution and sludge characteristics, energy consumption and electrode mass depletion w...

Journal: :international journal of environmental research 2012
r. daniel a.v.s. prabhakara rao

this paper is a preliminary communication of a study on removal and recovery of heavy metalsfrom industrial waste waters using electro-coagulation (ec) technique. the larger study envisages use of solarenergy for producing the d.c. current, and simple chemical methods of standard methods in chemistry like useof hydrochloric acid, hydrogen sulfide, collection of precipitate, incineration and get...

Journal: :iranian chemical communication 2015
ghasem karim-nezhad ali pashazadeh

in this research, we reported a novel modified carbon ceramic electrode (cce) using ni/al layered double hydroxide as modifier was fabricated by sol-gel technique. the ni/al layered double hydroxide modified sol gel derived carbon ceramic (ni/al ldh-sgd-cc) electrode was used for electrocatalytic oxidation of acetaldehyde. the oxidation of acetaldehyde happens at the potential where ni (iii) sp...

Journal: :Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology 2010
M Bikson Abhishek Datta Asif Rahman Jen Scaturro

In this issue, Moliadze and colleagues investigate the role of electrode montage in the induction of acute lasting excitability changes by transcranial Direction Current Stimulation (tDCS) and transcranial Random Noise Stimulation (tRNS); specifically they demonstrate that during weak transcranial electrical stimulation, the position of the ‘‘return” electrode affects neuro-modulation under the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید