نتایج جستجو برای: airway reactance

تعداد نتایج: 85503  

Journal: :iranian journal of allergy, asthma and immunology 0
babak amra froogh soltaninejad mohammad golshan

the impulse oscillation system (ios) measures respiratory impedance (zrs) in terms of resistance (rrs) and reactance (xrs) at multiples of 5 hz. these measurements can be used clinically to help diagnose and monitor respiratory disorders, independent of effort. there is, as yet, no information on reference values for ios in iranian adolescents. the predictive equation for resistance and impedan...

Journal: :anesthesiology and pain medicine 0
shoko nakano department of anesthesiology, osaka medical college, takatsuki, japan junko nakahira department of anesthesiology, osaka medical college, takatsuki, japan; department of anesthesiology, osaka medical college, 2-7 daigaku-machi, takatsuki, osaka 569-8686, japan. tel: +81-726831221, fax: +81-726846552 yosuke kuzukawa department of anesthesiology, osaka medical college, takatsuki, japan toshiyuki sawai department of anesthesiology, osaka medical college, takatsuki, japan toshiaki minami department of anesthesiology, osaka medical college, takatsuki, japan

background the forced oscillation technique (fot) is a non-invasive means of measuring respiratory resistance and reactance. we tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in fot parameters than a supraglottic airway device (sgd). methods forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder tu...

Journal: :Journal of applied physiology 2012
Vanessa J Kelly Nathan J Brown Scott A Sands Brigitte M Borg Gregory G King Bruce R Thompson

Airway distensibility appears to be unaffected by airway smooth muscle (ASM) tone, despite the influence of ASM tone on the airway diameter-pressure relationship. This discrepancy may be because the greatest effect of ASM tone on airway diameter-pressure behavior occurs at low transpulmonary pressures, i.e., low lung volumes, which has not been investigated. Our study aimed to determine the con...

2017
Shoko Nakano Junko Nakahira Yosuke Kuzukawa Toshiyuki Sawai Toshiaki Minami

BACKGROUND The forced oscillation technique (FOT) is a non-invasive means of measuring respiratory resistance and reactance. We tested our hypothesis that endotracheal intubation would cause more substantial preoperative increases in FOT parameters than a supraglottic airway device (SGD). METHODS Forty patients requiring general anesthesia and mechanical ventilation for transurethral bladder ...

Journal: :The Journal of allergy and clinical immunology 2012
Yixin Shi Anna S Aledia Ahramahzd V Tatavoosian Shruthi Vijayalakshmi Stanley P Galant Steven C George

BACKGROUND Previous reports suggest that the peripheral airways are associated with asthma control. Patient history, although subjective, is used largely to assess asthma control in children because spirometric results are many times normal values. Impulse oscillometry (IOS) is an objective and noninvasive measurement of lung function that has the potential to examine independently both small- ...

Journal: :Journal of applied physiology 1998
R Peslin C Duvivier

We have tested the feasibility of separating the airway (Zaw) and tissue (Zti) components of total respiratory input impedance (Zrs,in) in healthy subjects by measuring alveolar gas compression by body plethysmography (Vpl) during pressure oscillations at the airway opening. The forced oscillation set up was placed inside a body plethysmograph, and the subjects rebreathed BTPS gas. Zrs,in and t...

2017
Antonio Molino Francesca Simioli Anna Agnese Stanziola Mauro Mormile Maria Martino Maria D’Amato

BACKGROUND Small airways are considered the major site of airflow limitation in COPD. Impulse oscillometry (IOS) is a forced oscillation technique, which provides passive measurement of lung mechanics. It can differentiate small airway from large airway obstruction and is more sensitive than spirometry for peripheral airway disease. In this study the efficacy of the combination of Indacaterol/G...

2015
David Aronsson Roger Hesselstrand Gracijela Bozovic Dirk M. Wuttge Ellen Tufvesson

BACKGROUND Interstitial lung disease often occurs as an early complication of systemic sclerosis (SSc). The aim was to investigate whether impulse oscillometry (IOS) could be used to evaluate lung impairment in SSc. METHODS Seventy-eight SSc patients, of which 65 had limited cutaneous SSc (lcSSc) and 13 had diffuse cutaneous SSc (dcSSc), were subjected to high-resolution computed tomography (...

2013
Akemi Uchida Satoru Ito Béla Suki Hiroki Matsubara Yoshinori Hasegawa

The forced oscillation technique (FOT) is a useful tool to assess respiratory resistance and reactance during tidal breathing in patients with respiratory diseases, specifically asthma and chronic obstructive pulmonary disease. Although the FOT has been clinically used, results of respiratory impedance can be affected by various factors such as upper airway artifact. We investigated the effects...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید