نتایج جستجو برای: airtraq

تعداد نتایج: 253  

2014
Mikael Gellerfors Agneta Larsson Christer H Svensén Dan Gryth

BACKGROUND Difficulties with prehospital intubations have encouraged the development of indirect laryngoscopy techniques, facilitating laryngeal visualization. Airtraq® is a relatively new single-use indirect laryngoscope. The Airtraq® has been evaluated in several prehospital mannequin intubation trials. However, prehospital clinical experience with the device is limited. METHODS A retrospec...

Journal: :Canadian journal of anaesthesia = Journal canadien d'anesthesie 2011
Manuel Angel Gómez-Ríos Laura Nieto Serradilla

Combined Use of an Airtraq Optical Laryngoscope, Airtraq Video Camera, Airtraq Wireless Monitor, and a Fibreoptic Bronchoscope After Failed Tracheal Intubation Can J Anesth/J Can Anesth (2011) 58:411–412 Manuel Angel Gomez-Rıos, MD Laura Nieto Serradilla, MD Complejo Hospitalario Universitario A Coruna Spain This case report presents the simultaneous use of an Airtraq optical laryngoscope, Airt...

Journal: :Anaesthesia 2012
D Ranieri S M Filho S Batista P do Nascimento

This study compared intubation conditions produced by the Macintosh and Airtraq™ laryngoscopes when used in obese patients in the ramped position. One hundred and thirty-two patients having bariatric surgery were placed in the ramped position and randomly assigned to have their tracheas intubated using either the Macintosh (n=64) or an Airtraq (n=68) laryngoscope. Mean (SD) intubation times wer...

2017
Nadeem Raza Muazzam Hasan Syed Moeid Ahmed Shahjahan Bano Manazir Athar

BACKGROUND AND AIMS Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thus, we did a comparative study between McGrath and Airtraq videolaryngoscopes to evaluate their eff...

Journal: :Anesthesia and analgesia 2011
Pierangelo Di Marco Lorena Scattoni Annamaria Spinoglio Marta Luzi Alessandra Canneti Paolo Pietropaoli Carlo Reale

BACKGROUND The curved laryngoscope blade described by Macintosh in 1943 remains the most widely used device to facilitate tracheal intubation. The Airtraq laryngoscope is a new, single-use device for tracheal intubation. Several studies compared the use of Airtraq and Macintosh laryngoscopes in simulated intubation scenarios on manikins. We evaluated learning and performance of tracheal intubat...

Journal: :British journal of anaesthesia 2008
S K Ndoko R Amathieu L Tual C Polliand W Kamoun L El Housseini G Champault G Dhonneur

BACKGROUND The Airtraq laryngoscope is designed to allow visualization of the glottis without alignment of the oral, pharyngeal, and laryngeal axes. We hypothesized that this new airway device would facilitate tracheal intubation of morbidly obese patients. We compared tracheal intubation performance of standard Macintosh laryngoscope with the Airtraq laryngoscope in morbidly obese patients. ...

Journal: :Journal of the Royal Army Medical Corps 2008
J L Tong A J Gait M Woollard P G Nightingale M R Sharma

Practitioners providing pre-hospital care during civilian practice and on military operations may be required to perform airway management and tracheal intubation at floor level. It has been shown that intubation using the Airtraq laryngoscope is easier to learn than standard Macintosh laryngoscopy. We hypothesised that the Airtraq would be easier to use and have shorter intubation times than M...

2016
Li Wan Mingfeng Liao Li Li Wei Qian Rong Hu Kun Chen Chuanhan Zhang Wenlong Yao

BACKGROUND Many studies have shown Airtraq videolaryngoscope provided faster tracheal intubation and a higher success rate than other videolaryngoscopes. Recently, different types of videolaryngoscopes have been reported for use in double-lumen tube (DLT) intubation. However, the advantages and disadvantages between them remain undetermined for DLT intubation. In this study, we compared the Air...

2015
Thomas Hamp Thomas Stumpner Georg Grubhofer Kurt Ruetzler Rainer Thell Helmut Hager

INTRODUCTION Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq® laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq® laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release co...

Journal: :Anaesthesia 2009
Z I Arslan T Yildiz Z N Baykara M Solak K Toker

The aim of this study was to evaluate the effectiveness of the Airtraq and CTrach in lean patients with simulated cervical spine injury after application of a rigid cervical collar. Eighty-six consenting adult patients of ASA physical status 1 or 2, who required elective tracheal intubation were included in this study in a randomised manner. Anaesthesia was induced using 1 microg kg(-1) fentany...

نمودار تعداد نتایج جستجو در هر سال