نتایج جستجو برای: air kerma strength

تعداد نتایج: 408460  

2014
L. W. Zimmermann D. Allan Wilkinson

The purpose of this work was to develop a method for easily verifying that the activity or air kerma strength of pre-assembled eye plaques, used in the treatment of ocular melanomas, agrees with the activity or air kerma strength called for in the treatment plan. A Capintec CRC-7 Dose Calibrator with its standard vial/syringe sample holder was used to measure the activity of pre-assembled COMS ...

A. Bozkurt, G. Kemikler, H. Acun,

Background: This study aims to calculate the air-kerma strength (SK), the dose rate constant (∧) and the dose rate profiles of a Gammamed 12i Ir-192 source by using the Monte Carlo technique and to compare the dose rate values with those calculated by the Abacus HDR treatment planning system (TPS). Materials and Methods: Air-kerma strength (in units of U; 1 U= μGy m2 h-1) and the dose ra...

2013
Danielle R. Beaulieu David C. Medich Roger Steele

Brachytherapy describes a process where radioactive sources are inserted directly into the target area of a patient to treat disease. Before they can be used for treatment, brachytherapy sources must be calibrated such that medical physicists know their exact air kerma strength a quantity given by manufacturers as a standard. Each individual source must be measured before use. Therefore, medica...

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2010
Mohammad Taghi Bahreyni Toossi Mahdi Ghorbani Ali Asghar Mowlavi Mojtaba Taheri Mohsen Layegh Yasha Makhdoumi Ali Soleimani Meigooni

BACKGROUND Task group number 40 (TG-40) of the American Association of Physicists in Medicine (AAPM) has recommended calibration of any brachytherapy source before its clinical use. GZP6 afterloading brachytherapy unit is a (60)Co high dose rate (HDR) system recently being used in some of the Iranian radiotherapy centers. AIM In this study air kerma strength (AKS) of (60)Co source number thre...

D. Shahbazi-Gahrouei, M. Hosseinpour, M.B. Tavakoli,

Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...

Journal: :iranian journal of medical physics 0
koroush arbabi ph.d. student in medical physics, agricultural, medical & industrial research school (amirs), nuclear sciences & technology research institute (nstri), atomic energy organization of iran (aeoi), tehran, iran gholamreza raisali associate professor, nuclear engineering, radiation application research school (rars), nstri, aeoi masoomeh dehghani moghadam m.sc. in nuclear physics, deputy of nuclear research & technology, aeoi, tehran, iran mostafa ghafoori m.sc. in nuclear engineering, amirs, nstri, aeoi, tehran, iran arjang shahvar b.sc. in nuclear physics, amirs, nstri, aeoi, tehran, iran said hamidi assistant professor, nuclear physics dept., physics group, basic sciences faculty, arak university, arak, iran

introduction: well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. the chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. for the measurements, the brachytherapy sources are transferred to the middle of the tube. materials and methods: for designing the well type chamber, the measu...

2003
Stephen M. Seltzer Paul J. Lamperti Robert Loevinger Michael G. Mitch James T. Weaver Bert M. Coursey

The new U.S. measurement standard for the air-kerma strength from low-energy photon-emitting brachytherapy seed sources is formally described in detail. This instrument-based standard was implemented on 1 January 1999, with its salient features and the implications of differences with the previous standard given only through a series of informal communications. The Wide-Angle Free-Air Chamber (...

Journal: :iranian journal of radiation research 0
m.b. tavakoli department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran d. shahbazi-gahrouei department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran m. hosseinpour department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran

background: for an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. the usual method to determine these factors is thermo luminescent dosimeter (tld) dosimetry. nowadays, another more accurate method is known to be the monte carlo ...

Journal: :Circulation. Cardiovascular interventions 2014
Shikhar Agarwal Akhil Parashar Stephen G Ellis Frederick A Heupler Evan Lau E Murat Tuzcu Samir R Kapadia

BACKGROUND X-ray use in the catheterization laboratory is guided by the principle of as low as reasonably achievable. In accordance with this principle, we reduced the default fluoroscopic frame rate from 10 to 7.5 frames/s and increased the emphasis on the use of low-dose acquisition starting January 1, 2013. We aimed to study the impact of these measures on the total air kerma during diagnost...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید