The purpose of this work was to develop a method for easily verifying that the activity or air kerma strength of pre-assembled eye plaques, used in the treatment of ocular melanomas, agrees with the activity or air kerma strength called for in the treatment plan. A Capintec CRC-7 Dose Calibrator with its standard vial/syringe sample holder was used to measure the activity of pre-assembled COMS ...
Background: This study aims to calculate the air-kerma strength (SK), the dose rate constant (∧) and the dose rate profiles of a Gammamed 12i Ir-192 source by using the Monte Carlo technique and to compare the dose rate values with those calculated by the Abacus HDR treatment planning system (TPS). Materials and Methods: Air-kerma strength (in units of U; 1 U= μGy m2 h-1) and the dose ra...
Brachytherapy describes a process where radioactive sources are inserted directly into the target area of a patient to treat disease. Before they can be used for treatment, brachytherapy sources must be calibrated such that medical physicists know their exact air kerma strength a quantity given by manufacturers as a standard. Each individual source must be measured before use. Therefore, medica...
BACKGROUND Task group number 40 (TG-40) of the American Association of Physicists in Medicine (AAPM) has recommended calibration of any brachytherapy source before its clinical use. GZP6 afterloading brachytherapy unit is a (60)Co high dose rate (HDR) system recently being used in some of the Iranian radiotherapy centers. AIM In this study air kerma strength (AKS) of (60)Co source number thre...
Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...
introduction: well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. the chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. for the measurements, the brachytherapy sources are transferred to the middle of the tube. materials and methods: for designing the well type chamber, the measu...
The new U.S. measurement standard for the air-kerma strength from low-energy photon-emitting brachytherapy seed sources is formally described in detail. This instrument-based standard was implemented on 1 January 1999, with its salient features and the implications of differences with the previous standard given only through a series of informal communications. The Wide-Angle Free-Air Chamber (...
background: for an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. the usual method to determine these factors is thermo luminescent dosimeter (tld) dosimetry. nowadays, another more accurate method is known to be the monte carlo ...
BACKGROUND X-ray use in the catheterization laboratory is guided by the principle of as low as reasonably achievable. In accordance with this principle, we reduced the default fluoroscopic frame rate from 10 to 7.5 frames/s and increased the emphasis on the use of low-dose acquisition starting January 1, 2013. We aimed to study the impact of these measures on the total air kerma during diagnost...