نتایج جستجو برای: 6mv

تعداد نتایج: 216  

Journal: :International journal of radiation oncology, biology, physics 2006
Hidefumi Aoyama David Clark Westerly Thomas Rockwell Mackie Gustavo H Olivera Søren M Bentzen Rakesh R Patel Hazim Jaradat Wolfgang A Tome Mark A Ritter Minesh P Mehta

BACKGROUND This study was designed to evaluate the integral dose (ID) received by normal tissue from intensity-modulated radiotherapy (IMRT) for prostate cancer. METHODS AND MATERIALS Twenty-five radiation treatment plans including IMRT using a conventional linac with both 6 MV (6MV-IMRT) and 20 MV (20MV-IMRT), as well as three-dimensional conformal radiotherapy (3DCRT) using 6 MV (6MV-3DCRT)...

2017
Suresh Tamilarasu Madeswaran Saminathan S K Sharma Anjali P Abhinav Dewan

Aim: To evaluate the plan quality of 6MV unflattened (UFB) and flattened beam (FB) photon energy using AAA dose calculation algorithms for volumetric arc therapy. Materials and Methods: Plans were generated for bilateral carcinoma of breast and the dose prescribed was 50.4Gy in 28 fractions. Two different plans were made for each patient using 6MV FB and 6MV UFB. Dose calculations were performe...

2006

ID: 4805 Title: For small field Radiosurgery Intermediate Energy Photons (800kV) show superior dose distributions compared to megavoltage beams Purpose: Beam penumbra is significant when using stereotactic radiosurgery to treat small volumes with limited microscopic extensions. It is challenging to irradiate these lesions if a highly critical structure is in close contact with the target. Previ...

2005

ID: 3490 Title: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy Purpose: To investigate the computed non-tumor integral dose (NTID) delivered during treatment of prostate cancer with intensity modulated radiotherapy (IMRT) compared to three-dimensional conformal radiotherapy (3DCRT). Low and highenergy photon treatments were also evaluated in this study, as was helical tom...

Journal: :Medical physics 2016
A Qureshi S Tanny E Parsai N Sperling

PURPOSE As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accele...

Purpose: To study the benefits of Directional Bremsstrahlung Splitting (DBS) dose variance reduction technique in BEAMnrc Monte Carlo (MC) code for Oncor® linac at 6MV and 18MV energies. Materials and Method: A MC model of Oncor® linac was built using BEAMnrc MC Code and verified by the measured data for 6MV and 18MV energies of various field sizes. Then Oncor® machine was modele...

2008
Laurence E. Court Roy B. Tishler Aaron M. Allen Hong Xiang Mike Makrigiorgos Lee Chin

This work investigates the accuracy of skin dose calculations using the Eclipse treatment planning system. Skin dose was measured using micro-MOSFETs for a range of irradiation conditions (open fields, physical wedges, dynamic wedges, different SSDs) for 6MV and 10MV beams, and compared with the mean dose calculated to a 2mm thick "skin" structure for semi-cylindrical phantoms (representative o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید