نتایج جستجو برای: 60co

تعداد نتایج: 861  

2016
Yan Pan Gang Gao Jian Lei Ruan Jian Xiang Liu

Flow cytometry analysis was used to detect the changes of γH2AX protein expression in human peripheral blood lymphocytes. In the dose-effect study, the expression of γH2AX was detected 1 h after irradiation with 60Co γ-rays at doses of 0, 0.5, 1, 2, 4, and 6 Gy. Blood was cultivated for 0, 1, 2, 4, 6, 12, and 24 h after 4 Gy 60Co γ-rays irradiation for the time-effect study. At the same time, t...

Journal: :Nihon Naika Gakkai zasshi. The Journal of the Japanese Society of Internal Medicine 1964
G WAKISAKA

It was confirmed by fecal excretion test and Schilling's urinary excretion test using vitamin B@12 labelled with @60Co (@60Co-B@12) that the intestinal absorption of vitamin B@12 was markedly disturbed in patients with pernicious anemia. When @60Co-B@12 was given by mouth together with hog intrinsic factor in patients with pernicious anemia, the intestinal absorption of @60Co-B@12 was restored ...

Journal: :Journal of radiation research 1992
K Shizuma K Iwatani H Hashi T Oka H Morishima M Hoshi

Neutron-induced activities 60Co and 152Eu have been measured for samples collected from the Atomic-Bomb Dome locating at 161 m from the hypocenter of the Hiroshima Bomb. Specific activities 60Co/Co and 152Eu/Eu at the time of the detonation have been determined as 10.0 +/- 1.0 Bq mg-1 (steel sample S4) and 80 +/- 9 Bq mg-1 (granite sample G1), respectively. Detailed measurements of 60Co and 152...

Journal: :Journal of radiation research 1991
O Yamamoto T Jo M Sugiyama T Itoh

Radioresistant E. coli TGl harboring pUC 18 plasmid which was Ampicillin-resistant was exposed to 60Co gamma-rays or 3H beta-rays in saline to determine whether the relative biological effectiveness of 3H beta-rays is higher than one. After exposure to 60Co gamma-rays at a dose rate of 0.465 Gy/min, the D0 by colony formation was 145 Gy in the presence of Ampicillin in or absence from the agar ...

ژورنال: :سنجش و ایمنی پرتو 0
حمید روانبخش hamid ravanbakhsh department of physics, peyambare azam institute, islamic azad university of tehran, tehran, iranدانشگاه آزاد تهران مرکز، مجتمع پیامبر اعظم ، دانشکده علوم پایه ،گروه فیزیک ، ایران ، تهران حسین زمانی زینلی hossein zamani zeinali پژوهشکده پزشکی ، صنعتی و کشاورزی ،پژوهشگاه علوم و فنون هسته ای،سازمان انرژی اتمی ایران ، ایران،کرج علی اکبر میرزایی ali akbar mirzaii department of physics, peyambare azam institute, islamic azad university of tehran, tehran, iranدانشگاه آزاد تهران مرکز، مجتمع پیامبر اعظم ، دانشکده علوم پایه ،گروه فیزیک ، ایران ، تهران ارژنگ شاهور arjang shahvar پژوهشکده پزشکی ، صنعتی و کشاورزی ،پژوهشگاه علوم و فنون هسته ای،سازمان انرژی اتمی ایران ، ایران،کرج

در این طرح تحقیقاتی، طراحی، آماده سازی، کنترل کیفی و تولید چشمه استاندارد بسته و استوانه ای رادیوایزوتوپ 60co از طریق واکنش  60co (n,γ) 59co طبق استاندارد های بین المللی مورد مطالعه قرار گرفته است. پس از تولید چشمه های 60co، آزمون های کنترل کیفی شامل آزمون نشتی و آلودگی سطحی بر روی نمونه های تولیدی انجام گرفت، سپس فعالیت چشمه های تولیدی 60co  به وسیله اتاقک یونش کروی با حجم بزرگ 1 لیتری اندازه ...

Journal: :Physics in medicine and biology 1996
A R DuSautoy

A description is given of the UK primary standard graphite calorimeter system. The calorimeter measures absorbed dose to graphite for photon radiations from 60Co to 19 MV x-rays, and is the basis of the NPL therapy-level absorbed dose to water calibration service. Absorbed dose to graphite from the photon calorimeter has been compared with three other standards: an ionization chamber and cavity...

2014
J. Eduardo Villarreal‐Barajas Rao F.H. Khan

The objective of this study is to evaluate the suitability of recently introduced radiochromic film EBT3 for clinical dosimetry in the kilovoltage (kV) range. For this purpose, a kV X-ray irradiator, X RAD 320ix in the range 70 to 300 kVp, a clinical 60Co source, a 6 MV and an 18 MV X-ray clinical beam from a Varian linear accelerator were calibrated following AAPM dosimetry protocols. EBT3 fil...

Journal: :Medical physics 1999
X A Li

The peak scatter factor (PSF) for a photon beam is defined as the ratio of the total dose and the primary dose at the depth of dose maximum. The values of the PSF for photon beams ranging from 60Co to 24 MV are calculated using the EGS4 Monte Carlo technique, to avoid measurement difficulties. The calculation shows that the effect of SSD on PSF for high energy photon beams is not significant fo...

Journal: :Molecules 2014
Ke Zhang Zhibin Li Shaowen Zhu Qunfang Weng

Radio-(60Co), which emits γ rays, has been used worldwide in pest control. The aim of the present study was to analyze the effect of effective-low-power 60Co-γ irradiation on the enzymatic antioxidant system of the citrus red mite Panonychus citri. One day old female adults were exposed to 0.4 kGy 60Co-γ irradiation and on the, 6th h, 1st day, 2nd day, and 5th day post treatment, the mites were...

2017
Subhalaxmi Mishra T. Palani Selvam

PURPOSE To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. MATERIALS AND METHODS The brachytherapy sources investigated in this study are BEBIG High Dose...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید