نتایج جستجو برای: 6 mev electron beam

تعداد نتایج: 1335450  

Journal: :iranian journal of medical physics 0
hadis ansari mehr1 department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...

Azim Arbabi Hadis Ansari Mehr1, Mahmood Allahverdi Mohammad Hasan Zahmatkesh Saeid Bagheri

Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

2016
Juergen Meyer Matthew J. Nyflot Wade P. Smith Landon S. Wootton Lori Young Fei Yang Minsun Kim Kristi R. G. Hendrickson Eric Ford Alan M. Kalet Ning Cao Claire Dempsey George A. Sandison

Monthly QA is recommended to verify the constancy of high-energy electron beams generated for clinical use by linear accelerators. The tolerances are defined as 2%/2 mm in beam penetration according to AAPM task group report 142. The practical implementation is typically achieved by measuring the ratio of readings at two different depths, preferably near the depth of maximum dose and at the dep...

K. Adinehvand, M.H. Zahmatkesh, M.R Aghamiri, S. Bagheri, Sh. Akhlaghpour,

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

Hamid Reza Baghani, Nematollah Heidarloo, Seyed Mahmoud Reza Aghamiri

Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...

Farideh Farokhi Moghadam

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

Journal: :jentashapir journal of health research 0
mohammad javad tahmasebi birgani department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran mansour zabihzadeh department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; student research committee, ahvaz jundishapur university of medical sciences, ahvaz, ir lran; department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran. tel: +98-9125032283 sholeh arvandi department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran elahe gharibreza department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran

conclusions using the maximum dose depth from pdd curves and the inverse square law, the required ssdeff to calculate the dose distribution of the electron beam can be calculated. objectives the aim of this study was to determine the effective source-surface distance (ssdeff) of an electron linear accelerator (linac), and its dependence on energy and depth. materials and methods a varian linac ...

Journal: :Journal of the Egyptian National Cancer Institute 2004
Tarek Shouman Zeinab El-Taher

OBJECTIVE Development of a technique for treating whole-body skin using linear accelerator with electron beam energy of 6-MeV at a short treatment distance. MATERIAL AND METHODS The 6 MeV high dose rate total skin electron irradiation mode on a linear accelerator was used. Beam profiles and percentage depth doses in the patient plane were measured for different beam angulations. RESULTS At ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید